Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.Keywords
This publication has 65 references indexed in Scilit:
- DiscussionJournal of Biomechanics, 1999
- Electrophysiological properties of dual atrioventricular nodes in patients with right atrial isomerism.Heart, 1995
- Three-dimensional visualization of velocity profiles in the human main pulmonary artery with magnetic resonance phase-velocity mappingAmerican Heart Journal, 1994
- A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesisJournal of Biomechanics, 1994
- Two-dimensional mitral flow velocity profiles in pig models using epicardial doppler echocardiographyJournal of the American College of Cardiology, 1994
- Size and motion of the mitral valve annulus in man. I. A two-dimensional echocardiographic method and findings in normal subjects.Circulation, 1981
- Numerical Study of the Steady Axisymmetric Flow Through a Disk-Type Prosthetic Heart Valve in an Aortic-Shaped ChamberJournal of Biomechanical Engineering, 1979
- Numerical Study of the Steady Axisymmetric Flow Through a Disk-Type Prosthetic Heart Valve in a Constant Diameter ChamberJournal of Biomechanical Engineering, 1977
- Computer prediction of thrombogenic sites for a tilting-disc prosthetic heart valveComputers and Biomedical Research, 1977
- Prolapse of the mitral valve (floppy valve) associated with Ebstein's anomaly of the tricuspid valveThe American Journal of Cardiology, 1976