Wear in Retrieved Charnley Acetabular Sockets
- 1 September 1996
- journal article
- editorial
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 210 (3) , 197-207
- https://doi.org/10.1243/pime_proc_1996_210_413_02
Abstract
One hundred and twenty-nine Charnley acetabular components were acquired at the time of revision surgery and a tribological investigation undertaken. The relative occurrence of pitting in the unworn and worn regions of the sockets suggest that most of the cement ingress occurs during the early part of the service life. The penetration depth of the explanted sockets was determined using the shadowgraph technique. Observation of the profiles in the wear planes suggest that, in general, the creep component was not a significant proportion of the overall change in the inner bore of the socket. Using weighted ordinary least squares regression, in which the intercept was not assumed to be zero, mean penetration and wear volume rates of 0.20 (SE = 0.02) mm/year and 55 (SE = 5) mm3/year, respectively, were recorded and are in agreement with other retrieval studies. In neither case was the intercept found to be significantly different from zero. A mean clinical wear factor, kclinical, equal to 2.1 (SE = 0.2) × 10-6 mm3/N m was calculated which is considerably larger than that found in laboratory experiments which purport to reflect in vivo conditions. In this analysis, a significant positive intercept was observed [96 (SE = 36) mm3] and may be evidence of the small initial penetration due to creep reported in simulator experiments. A strong positive association between kclinical and the arithmetical mean roughness, Ra, of the femoral head was also demonstrated although the rate of change was not as great as that cited for laboratory experiments.Keywords
This publication has 41 references indexed in Scilit:
- Wear mechanisms of UHMWPE in total joint replacementsWear, 1995
- The effect of transfer film and surface roughness on the wear of lubricated ultra-high molecular weight polyethyleneClinical Materials, 1993
- Wear of the polyethylene acetabular cup: Metallic and ceramic heads compared in a hip simulatorActa Orthopaedica, 1993
- Polyethylene wear in unicondylar knee prosthesesActa Orthopaedica, 1992
- The Mechanism of Loosening of Cemented Acetabular Components in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1992
- Design and Development of a Versatile Hip Joint Simulator and a Preliminary Assessment of Wear and Creep in Charnley Total Replacement Hip JointsEngineering in Medicine, 1988
- The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethyleneBiomaterials, 1986
- Influence of Counterface Topography on the Wear of Ultra High Molecular Weight Polyethylene Under Wet or Dry ConditionsPublished by American Chemical Society (ACS) ,1985
- A comparison of RCH 1000 and Hi-Fax 1900 ultra-high molecular weight polyethylenesBiomaterials, 1985
- Wear studies on prosthetic materials using the pin-on-disc machineBiomaterials, 1982