Armature Leakage Reactance of Synchronous Machines
- 1 April 1935
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the American Institute of Electrical Engineers
- Vol. 54 (4) , 378-381
- https://doi.org/10.1109/T-AIEE.1935.5056993
Abstract
An extension of the Potier method of testing for armature leakage reactance of synchronous machines is presented in this paper, wherein it is shown that the easily tested for Potier reactance varies considerably and therefore has a limited field of usefulness. It is further shown that if the Potier reactance is measured at high values of field current, the armature leakage reactance is closely approximated and a more valuable test results.Keywords
This publication has 3 references indexed in Scilit:
- Calculation of Synchronous Machine Constants- Reactances and Time Constants Affecting Transient CharacteristicsTransactions of the American Institute of Electrical Engineers, 1931
- The Calculation of the Armature Reactance of Synchronous MachinesTransactions of the American Institute of Electrical Engineers, 1928
- Reactance of Synchronous Machines and its ApplicationsTransactions of the American Institute of Electrical Engineers, 1918