Treatment of Malignant Ventricular Arrhythmias with the Automatic Implantable Cardioverter Defibrillator
- 1 May 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 209 (5) , 635-641
- https://doi.org/10.1097/00000658-198905000-00017
Abstract
Twenty-eight patients with malignant ventricular arrhythmias were treated with the automatic implantable cardioverter-defibrillator (AICD) in a 14-month period. Thirteen patients were resuscitated from a ventricular fibrillation (VF) episode. Fifteen patients presented with ventricular tachycardia (VT) refractory to medical therapy. The etiology was coronary artery disease in 23 of 28 patients (82%), dilated cardiomyopathy in 2 of 28 patients (7%), sarcoidosis in 2 of 28 patients, and 1 patient in 28 had lupus erythmatosis. The mean left ventricular ejection fraction was 29%. A total of 27 of 28 patients (96%) patients had inducible ventricular tachycardia using programmed stimulation. The patients considered for AICD implant failed a mean of 3.6 antiarrhythmic drugs. Rate counting and defibrillating leads were inserted through a lateral thoracotomy in 17 patients and a mediansternotomy incision in 11 patients in conjunction with another cardiac procedure in 10 patients. The generators were positioned in a subcutaneous pocket beneath the left costal margin. There were no operative deaths. The mean follow-up was 6.7 months (range 1 to 14) with no VT/VF deaths in patients with defibrillators. The study demonstrated that AICD is an effective device for prevention of sudden cardiac death.Keywords
This publication has 27 references indexed in Scilit:
- The Automatic Implantable Cardioverter Defibrillator: Results, Observations, and CommentsPacing and Clinical Electrophysiology, 1986
- Cardiac arrest treated with a new automatic external defibrillator by out-of-hospital first respondersThe American Journal of Cardiology, 1986
- The Automatic Implantable Cardioverter-Defibrillator: Efficacy, Complications, and Device FailuresAnnals of Internal Medicine, 1986
- The implanted defibrillator: relation of defibrillating lead configuration and clinical variables to defibrillation thresholdJournal of the American College of Cardiology, 1985
- Comparative efficacy of transvenous cardioversion and pacing in patients with sustained ventricular tachycardia: a prospective, randomized, crossover study.Circulation, 1985
- Survival of out-of-hospital cardiac arrest with early initiation of cardiopulmonary resuscitationThe American Journal of Emergency Medicine, 1985
- Usefulness of electrophysiologic testing in evaluation of amiodarone therapy for sustained ventricular tachyarrhythmias associated with coronary heart diseaseThe American Journal of Cardiology, 1985
- Initiating events of sudden cardiac death.1985
- Clinical characteristics of sudden death: implications for survival.1985
- Personnel and equipment required for electrophysiologic testing. Report of the Committee on Electrocardiography and Cardian Electrophysiology, Council on Clinical Cardiology, the American Heart Association.1984