Palmar Plate Fixation of AO Type C2 Fracture of Distal Radius Using a Locking Compression Plate –A Biomechanical Study in a Cadaveric Model
- 1 June 2003
- journal article
- research article
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 28 (3) , 263-266
- https://doi.org/10.1016/s0266-7681(03)00011-1
Abstract
The stability of palmar plate fixation using a locking compression T-plate was compared with that of a conventional palmar T-plate and a dorsal T-plate in a cadaveric model of an AO type C2 fracture of distal radius. The wrist axial load transmission through the radius was tested for each fixation. The results show that, under 100N axial load, the palmar locking compression T-plate restores stability comparable to that of the intact radius, and is superior to conventional palmar or dorsal T-plates.Keywords
This publication has 15 references indexed in Scilit:
- Palmar Plating for Dorsally Displaced Fractures of the Distal RadiusPublished by Wolters Kluwer Health ,2002
- CONSERVATIVE TREATMENT OF INTRA-ARTICULAR FRACTURES OF THE DISTAL RADIUS — FACTORS AFFECTING FUNCTIONAL OUTCOMEHand Surgery, 2000
- COMMINUTED INTRA-ARTICULAR FRACTURE OF THE DISTAL RADIUS — THE TECHNIQUE OF OPEN REDUCTION AND INTERNAL FIXATION WITH PLATINGHand Surgery, 1999
- Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the π plate on the volar surface of the distal radiusThe Journal of Hand Surgery, 1999
- Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius: A brief reportThe Journal of Hand Surgery, 1998
- Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fracturesThe Journal of Hand Surgery, 1998
- Open reduction and internal fixation of displaced intraarticular fractures of the distal radius: 31 patients followed for 3-7 yearsActa Orthopaedica, 1997
- Fractures of the distal end of the radius.Journal of Bone and Joint Surgery, 1991
- Clinical and microangiographic studies on rupture of the E.P.L. tendon after distal radial fracturesJournal of Hand Surgery (European Volume), 1990
- Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radiusThe Journal of Hand Surgery, 1990