Surgical robotics: Impact of motion scaling on task performance
- 31 December 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 199 (6) , 863-868
- https://doi.org/10.1016/j.jamcollsurg.2004.08.027
Abstract
Background Robotic systems have been shown to enhance surgical dexterity, and the advantage has been hypothesized to result from the removal of tremor and addition of motion scaling. But these purported gains over traditional laparoscopic instrumentation have not been quantified. This study was designed to compare the surgical accuracy between conventional laparoscopic instruments and a robotic surgical system and evaluate the importance of tremor filtration (TF) and motion scaling (MS) in these robotic systems. Study design Fifteen participants with no previous surgical experience were enrolled. To simulate microsurgical techniques, a 29-gauge needle was used to puncture the center of 6 microscopic archery targets (circle diameters 0.5, 1.5, and 2.5 mm). The robotic system was configured to three different degrees of MS and compared with the unassisted laparoscopic platforms in accuracy. Results Accuracy with robotic assistance with TF alone (1:1 MS) was not significantly different from unassisted laparoscopic control. Both moderate (2.5:1) and fine (7:1) MS significantly improved accuracy over traditional laparoscopic control (p < 0.001 for both). Robotic assistance with MS equalized the performance of both hands (p = 0.03) in precision, and manual laparoscopy demonstrated no statistical difference in handedness (p = 0.80). Conclusions Motion scaling, rather than tremor filtration, plays the major role in the enhanced accuracy seen in robotic surgical systems. Robotic assistance with MS significantly improved accuracy above laparoscopic instruments alone and robotic assistance with tremor filtration alone. MS also creates ambidexterity in an otherwise unidextrous population, optimizing the surgeon’s ability to undertake tasks requiring microsurgical accuracy.Keywords
This publication has 6 references indexed in Scilit:
- Robotic cardiac surgery: overviewSurgical Clinics of North America, 2003
- The effect of robotic assistance on learning curves for basic laparoscopic skillsThe American Journal of Surgery, 2002
- A Steady-Hand Robotic System for Microsurgical AugmentationThe International Journal of Robotics Research, 1999
- Anastomotic complications in minimally invasive coronary bypass graftingThe Annals of Thoracic Surgery, 1997
- Skill Acquisition and Assessment for Laparoscopic SurgeryArchives of Surgery, 1997
- A Prospective Analysis of 1518 Laparoscopic CholecystectomiesNew England Journal of Medicine, 1991