Application of the Monte Carlo integration (MCI) method for calculation of the anisotropy of brachytherapy sources
- 1 June 1998
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (6) , 1783-1801
- https://doi.org/10.1088/0031-9155/43/6/029
Abstract
Source anisotropy is a very important factor in the brachytherapy quality assurance of high-dose rate (HDR) afterloading stepping sources. If anisotropy is not taken into account then doses received by a brachytherapy patient in certain directions can be in error by a clinically significant amount. Experimental measurements of anisotropy are very labour intensive. We have shown that within acceptable limits of accuracy, Monte Carlo integration (MCI) of a modified Sievert integral (3D generalization) can provide the necessary data within a much shorter time scale than can experiments. Hence MCI can be used for routine quality assurance schedules whenever a new design of HDR or PDR is used for brachytherapy afterloading. Our MCI calculation results are compared with published experimental data and Monte Carlo simulation data for microSelectron and VariSource sources. We have shown not only that MCI offers advantages over alternative numerical integration methods, but also that treating filtration coefficients as radial distance-dependent functions improves Sievert integral accuracy at low energies. This paper also provides anisotropy data for three new sources, one for the microSelectron-HDR and two for the microSelectron-PDR, for which data are currently not available. The information we have obtained in this study can be incorporated into clinical practice.Keywords
This publication has 20 references indexed in Scilit:
- Dosimetric characteristics of a new high‐intensity source for remote afterloadingMedical Physics, 1997
- Anisotropy of an high dose rate source measured with a miniature ionization chamberMedical Physics, 1997
- Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43Medical Physics, 1995
- Anisotropy measurements of a high dose rate Ir‐192 source in air and in polystyreneMedical Physics, 1994
- A comparison of radial dose functions for 103Pd, 125I, 145Sm, 241Am, 169Yb, 192Ir, and 137Cs brachytherapy sourcesInternational Journal of Radiation Oncology*Biology*Physics, 1992
- A technique for the local measurement of air kerma rate from small Caesium-137 sourcesThe British Journal of Radiology, 1991
- Messung der Kenndosisleistung punkt- und linienförmiger HDR-192-Ir-Afterloadingstrahler mit einem PMMA-ZylinderphantomZeitschrift für Medizinische Physik, 1991
- Comparison of measured and calculated dose distributions around an iridium-192 wireMedical Physics, 1988
- Dose distributions around cylindrical 2 4 1 Am sources for a clinical intracavitary applicatorMedical Physics, 1987
- The Effective Attenuation in Water of the Gamma Rays of Gold 198, Iridium 192, Cesium 137, Radium 226, and Cobalt 60Radiology, 1968