Dysfunction of Implantable Defibrillators Caused by Slot Machines
- 1 January 1997
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 20 (1) , 212-214
- https://doi.org/10.1111/j.1540-8159.1997.tb04845.x
Abstract
The electrogram storage is a feature offered by the last generation of defibrillators, which enables the physician to establish whether the sensed episode and the electrical therapy delivered by the device was appropriate. The incidence of electromagnetic interferences may be higher than initially suspected with the latest generation of defibrillators. Such interference was documented in 4 out of 100 patients over a 24‐month period. The electrical interference occurred in all four of them, while they were playing with slot machines. In the RR interval history, irregular QRS sensing of variable frequency was documented in some episodes. The intervals were irregular and nonphysiological, satisfying the rate cut‐off criteria in an intermittent and nonsustained way. There maybe high risk of electromagnetic interference between slot machines and defibrillators. Our experience calls for a warning to all defibrillator patients and, perhaps some regulatory intervention.Keywords
This publication has 12 references indexed in Scilit:
- Advances in follow-up techniques for implantable defibrillatorsAmerican Heart Journal, 1994
- Inappropriate Discharge By an Implantable Cardioverter Defibrillator: Recognition of Myopotential Sensing Using Telemetered Intracardiac ElectrogramsPacing and Clinical Electrophysiology, 1994
- Importance of abortive shock capability with electrogram storage in cardioverter-defibrillator devicesJournal of the American College of Cardiology, 1993
- ICD Data Storage: Value in Arrhythmia ManagementPacing and Clinical Electrophysiology, 1993
- Arrhythmias induced by device antitachycardia therapy due to diagnostic nonspecificityJournal of the American College of Cardiology, 1991
- The automatic implantable cardioverter-defibrillator: Evaluating suspected inappropriate shocksJournal of the American College of Cardiology, 1986
- Unipolar pacer artifacts induced failure of an automatic implantable cardioverter/defibrillator to detect ventricular fibrillationThe American Journal of Cardiology, 1986
- Clinical Performance of the Implantable Cardioverter‐DefibrillatorPacing and Clinical Electrophysiology, 1984
- Potential Hazards of Implanted Devices for the Electrical Control of TachyarrhythmiasPacing and Clinical Electrophysiology, 1984