Influence of Environmental Concentrations of NO on the Exhaled NO Test
- 1 October 1998
- journal article
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 158 (4) , 1299-1301
- https://doi.org/10.1164/ajrccm.158.4.9712078
Abstract
Measurement of levels of exhaled nitric oxide (NO) has been proposed as a noninvasive method for evaluating the degree of airway inflammation in asthmatic patients. Some concern in the interpretation of results of such measurement may arise from possible interference by high environmental concentrations of NO inhaled by these patients. The aim of this study was to verify whether environmental concentrations of NO in the range from 0 to 150 ppb can influence levels of exhaled NO. We tested two groups of subjects. The first group, consisting of 16 subjects, was tested when environmental levels of NO were from 0 to 3 ppb and from 20 to 60 ppb, and exhaled NO mean ppb (+/- SEM) levels were 9.81 +/- 1.43 and 9.78 +/- 1.47 (p = ns) (mean +/- SEM), respectively. The second group, consisting of 30 subjects, was tested at ambient NO concentrations of 0 to 3 ppm, 80 to 100 ppm, and 120 to 150 ppb, and for 18 of these subjects who underwent testing under all three conditions investigated, the mean levels of exhaled NO were 9.23 +/- 1.51, 7.78 +/- 1.19, and 9.33 +/- 1.55 ppb (p = ns), respectively. The results of this study suggest that significantly different ambient levels of NO have no effect on levels of exhaled NO.Keywords
This publication has 10 references indexed in Scilit:
- Exhaled and nasal nitric oxide measurements: recommendations. The European Respiratory Society Task ForceEuropean Respiratory Journal, 1997
- Measurement of expired nitric oxide levels in childrenPediatric Pulmonology, 1996
- Exhaled nitric oxideCurrent Opinion In Anesthesiology, 1996
- Increased exhaled nitric oxide in asthma is mainly derived from the lower respiratory tract.American Journal of Respiratory and Critical Care Medicine, 1996
- Measurement of exhaled nitric oxide by three different techniques.American Journal of Respiratory and Critical Care Medicine, 1996
- Changes in the dose of inhaled steroid affect exhaled nitric oxide levels in asthmatic patientsEuropean Respiratory Journal, 1996
- Increased nitric oxide in exhaled air of asthmatic patientsPublished by Elsevier ,1994
- Measurement of exhaled nitric oxide in man.Thorax, 1993
- Reaction of nitric oxide with heme proteins and model compounds of hemoglobinBiochemistry, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986