Performances of high numerical aperture water and oil immersion objective in deep‐tissue, multi‐photon microscopic imaging of excised human skin
- 10 December 2003
- journal article
- topical paper
- Published by Wiley in Microscopy Research and Technique
- Vol. 63 (1) , 81-86
- https://doi.org/10.1002/jemt.10431
Abstract
Multi‐photon fluorescence microscopy (MPFM) is a powerful technique for imaging scattering, biological specimens in depth. In addition to the sectioning effect generated by the point‐like excitation volume, the near‐infrared wavelengths used for multi‐photon excitation allow deeper penetration into optically turbid specimens. In physiological specimens, the optical properties such as the scattering coefficients and refractive indices are often heterogeneous. In these specimens, it is not clear which type of immersion objective can provide optimized images in‐depth. In particular, in‐depth dermatological imaging applications using MPFM requires such optimization to obtain qualitative and quantitative information from the skin specimens. In this work, we address this issue by comparing the performances of two common types of high numerical aperture (NA) objectives: water‐immersion and oil‐immersion. A high‐quality water‐immersion objective (Zeiss, 40× C‐Apochromat, NA 1.2) and a comparable oil‐immersion objective (Zeiss, 40× Fluar, NA 1.25) were used for in‐depth imaging of autofuorescent excised human skin and sulforhodamine B treated human skin specimens. Our results show that in the epidermal layers, the two types of immersion objectives perform comparably. However, in the dermis, multi‐photon imaging using the oil immersion objective results in stronger fluorescence detection. These observations are most likely due to the degraded point‐spread‐function (PSF) caused by refractive index mismatch between the epidermis and the dermis. Microsc. Res. Tech. 63:81–86, 2004.Keywords
This publication has 16 references indexed in Scilit:
- Characterizing point spread functions of two-photon fluorescence microscopy in turbid mediumJournal of Biomedical Optics, 2003
- Influence of optical properties on two-photon fluorescence imaging in turbid samplesApplied Optics, 2000
- Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomographyJournal of Biomedical Optics, 2000
- Imaging of optically thick specimen using two-photon excitation microscopyMicroscopy Research and Technique, 1999
- Imaging properties in two-photon excitation microscopy and effects of refractive-index mismatch in thick specimensApplied Optics, 1999
- Multiphoton Excitation Provides Optical Sections from Deeper within Scattering Specimens than Confocal ImagingBiophysical Journal, 1998
- Multiphoton excitation fluorescence microscopy and spectroscopy of in vivo human skinBiophysical Journal, 1997
- Three‐dimensionally resolved NAD(P)H cellular metabolic redox imaging of the in situ cornea with two‐photon excitation laser scanning microscopyJournal of Microscopy, 1995
- Aberrations in confocal fluorescence microscopy induced by mismatches in refractive indexJournal of Microscopy, 1993
- Two-Photon Laser Scanning Fluorescence MicroscopyScience, 1990