Hearing Threshold Difference between Ears and Risk of Acoustic Tumor
- 1 December 1991
- journal article
- research article
- Published by Wiley in Otolaryngology -- Head and Neck Surgery
- Vol. 105 (6) , 814-817
- https://doi.org/10.1177/019459989110500607
Abstract
This study addresses the question, what difference in hearing between ears puts a patient at sufficient risk of acoustic tumor to warrant further diagnostic tests? The subjects were 210 patients with surgically confirmed unilateral acoustic tumors and a control group comprised of 112 patients referred for audiometry. Hearing thresholds were determined at octave intervals from 250 Hz to 8 kHz. The threshold in the nonsuspect ear was subtracted from the threshold in the suspect ear. The rank order in effectiveness for threshold difference was: 2 kHz, 4 kHz, 1 kHz, 8 kHz, 500 Hz, and 250 Hz. We found that the most effective diagnostic strategy was to refer patients for magnetic resonance imaging if their average threshold difference at 1 to 8 kHz was 20 dB or greater and refer patients for auditory brainstem response testing if their average threshold was 5 to 20 dB.Keywords
Funding Information
- Virginia Mason Medical Center
This publication has 6 references indexed in Scilit:
- Acoustic Neuroma: A Cost‐Effective ApproachOtolaryngology -- Head and Neck Surgery, 1990
- Decision Analysis of Auditory Brainstem Responses and Rotational Vestibular Tests in Acoustic Tumor DiagnosisOtolaryngology -- Head and Neck Surgery, 1987
- MEASURES OF GAIN IN CERTAINTY FROM A DIAGNOSTIC TESTAmerican Journal of Epidemiology, 1985
- Acoustic Tumor Detection With Brain Stem Electric Response AudiometryJAMA Otolaryngology–Head & Neck Surgery, 1977
- Sudden sensori‐neural hearing impairment: A report of 1,220 casesThe Laryngoscope, 1976