Around-the-Clock, Rapid Diagnosis of Influenza by Means of Membrane Chromatography Antigen Testing Confirmed by Polymerase Chain Reaction
- 1 February 2008
- journal article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 29 (2) , 177-179
- https://doi.org/10.1086/526446
Abstract
One rapid membrane chromatography test and 2 immunofluorescence tests were compared with polymerase chain reaction as tools for the diagnosis of influenza in 277 patients treated in an emergency department. The sensitivity on days 1-3 of symptoms was 71% for the rapid membrane chromatography test, 70% for the first immunofluorescence test, and 79% for the second immunofluorescence test. Rapid tests are useful for round-the-clock identification of influenza, with follow-up polymerase chain reaction used for confirmation.Keywords
This publication has 8 references indexed in Scilit:
- Lack of Discriminating Signs and Symptoms in Clinical Diagnosis of Influenza of Patients Admitted to the HospitalInfection, 2007
- Impact of Rapid Diagnosis on Management of Adults Hospitalized With InfluenzaArchives of internal medicine (1960), 2007
- Comparison of the NOW Influenza A & B, NOW Flu A, NOW Flu B, and Directigen Flu A+B assays, and immunofluorescence with viral culture for the detection of influenza A and B virusesDiagnostic Microbiology and Infectious Disease, 2007
- Relevance of Influenza A Virus Detection by PCR, Shell Vial Assay, and Tube Cell Culture to Rapid Reporting ProceduresJournal of Clinical Microbiology, 2006
- Does This Patient Have Influenza?JAMA, 2005
- Comparison of Binax NOW and Directigen for rapid detection of influenza A and BJournal of Clinical Virology, 2004
- Influenza and the Winter Increase in Mortality in the United States, 1959-1999American Journal of Epidemiology, 2004
- Nosocomial transmission of influenzaOccupational Medicine, 2002