Oxygen tension and consumption measured by a tc‐Po2 electrode on heated skin before and after epidermal stripping
- 1 July 1987
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 31 (5) , 362-369
- https://doi.org/10.1111/j.1399-6576.1987.tb02585.x
Abstract
Oxygen tensions, cutaneous blood flow rate, and skin oxygen consumption rate were determined by tc-PO2 measurements at an electrode temperature of 45.degree. C. The epidermal surface was stripped by 50 applications of adhesive plaster to the surface. Ten healthy, normotensive adults were examined. Cutaneous blood flow rate was 41.2 .+-. 8.6 ml .cntdot. (100 g)-1 .cntdot. min-1 before and 42.8 .+-. 5.9 ml .cntdot. (100 g)-1 .cntdot. min-1 after epidermal stripping. Oxygen consumption before stripping was 0.327 .+-. 0.65 ml O2 .cntdot. (100 g)-1 .cntdot. min-1, and after stripping it was determined at two different saturation levels to be 0.208 .+-. 0.072 ml O2 .cntdot. (100 g)-1 .cntdot. min-1 and 0.251 .+-. 0.096 ml O2 .cntdot. (100 g)-1 .cntdot. min-1. Capillary temperature was estimated to be approximately 43.degree. C before and after stripping. At this temperature mean arterial PO2 was estimated to be 18.1 kPa (136 mmHg), which would be reduced by the computed local metabolism to a mean capillary PO2 of 14.4 kPa (108 mmHg) before stripping and 15.2 kPa (114 mmHg) after. Stripping increased mean skin PO2 from 10.9 .+-. 0.6 kPa (82.3 .+-. 4.7 mmHg) to 14.6 .+-. 1.0 kPa (109.4 .+-. 7.7 mmHg). Thus, stripping eliminated 82% of the gradient between the capillaries and electrode while reducing the computed oxygen consumption by 23-36%. It is concluded that the epidermal membrane is a significant barrier to oxygen diffusion and that the transcutaneous oxygen electrode has a significant effect on skin. PO2 owing to its own even low oxygen consumption. This will reduce the observed skin PO2 significantly.Keywords
This publication has 16 references indexed in Scilit:
- A Combined tc-Po2and Skin Blood Flow SensorActa Anaesthesiologica Scandinavica, 1985
- Determination of Skin Blood Flow by133Xe Washout and by Heat Flux from a Heated tc‐Po2ElectrodeActa Anaesthesiologica Scandinavica, 1984
- Viability in split-skin biopsies measured by a surface oxygen electrodeScandinavian Journal of Clinical and Laboratory Investigation, 1984
- Capillary Blood Temperature in Transcutaneous PO2MeasurementsActa Anaesthesiologica Scandinavica, 1981
- Diffusion Processes Invalidating the Intra-arterial Krypton-85 Beta-Particle Clearance Method for Measurement of Skin Blood Flow in ManCirculation Research, 1967
- The oxygen tension gradient across human epidermisRespiration Physiology, 1967
- The systemic oxygen supply to the surface of human skinRespiration Physiology, 1967
- The dynamics of changes in dermal oxygen tensionRespiration Physiology, 1966
- Solubility of Carbon Dioxide, Krypton, and Xenon in Aqueous SolutionJournal of Pharmaceutical Sciences, 1964
- Observations on Regeneration of the Skin Barrier**From the Departments of Dermatology, Boston University School of Medicine, Boston, Massachusetts and Medical School, University of Miami, Miami, Florida.This work was supported by grants A-5779, A-5924 and 2G-224 from the National Institutes of Health and by U. S. Army Contract No. DA-49-007-MD-731.Journal of Investigative Dermatology, 1962