Computer Fitting of Germanium Thermometer Characteristics
- 1 June 1970
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 41 (6) , 835-842
- https://doi.org/10.1063/1.1684659
Abstract
Of the various kinds of dopedgermanium investigated for low temperature resistance thermometry, arsenic doping has been found most satisfactory in providing adequate sensitivity over the temperature range from less than 1 to a little over 100 K. Such sensors are highly reproducible as well as sensitive, but for accurate thermometry it has been a disadvantage that the relationship between sensor resistance R and absolute temperature T cannot be expressed accurately in analytic form. However, the relationship can be expressed within close limits over wide temperature ranges by polynomials of the form log 10 R= ∑ i=0 n A j ( log 10 T) i .For an optimum representation, it is necessary to make judicious choices both of the polynomial degree and the temperature range. Insistence on a single polynomial over the entire 1–100 K range produces a solution with spurious oscillations of rms amplitude some 0.3% of the absolute temperature. Such spurious oscillations can be reduced to an amplitude of a few parts in 104 of temperature by using one polynomial for the 1–20 K range and a second polynomial for T≳15 K (thus affording a small overlap region between the two polynomials). The markedly inferior results of using different temperature ranges and a different polynomial regression procedure are illustrated.Keywords
This publication has 27 references indexed in Scilit:
- Comparison Between Gas Thermometer, Acoustic, and Platinum Resistance Temperature Scales Between 2 and 20 KMetrologia, 1968
- Thermal time constants of germanium thermometers at liquid helium temperaturesCryogenics, 1967
- Diffused Germanium Resistors for Thermometry in 20 to 70°K RangeReview of Scientific Instruments, 1966
- Acoustical Thermometer and the National Bureau of Standards Provisional Temperature Scale 2–20 (1965)Metrologia, 1966
- Low Temperature Germanium Resistance ThermometryReview of Scientific Instruments, 1966
- Temperature-Resistance Relation for Germanium ThermometersReview of Scientific Instruments, 1966
- Optimal Spacing and Weighting in Polynomial PredictionThe Annals of Mathematical Statistics, 1964
- The Spacing of Observations in Polynomial RegressionThe Annals of Mathematical Statistics, 1958
- The Magneto-Resistance Effect in Oriented Single Crystals of GermaniumPhysical Review B, 1951
- Establishment of a temperature scale for the calibration of thermometers between 14 degrees and 83 degrees KJournal of Research of the National Bureau of Standards, 1939