In vitro assessment of infant pulmonary function equipment
- 1 April 1995
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 19 (4) , 205-213
- https://doi.org/10.1002/ppul.1950190404
Abstract
Commercially available automated pulmonary monitors are used increasingly in neonatal intensive care units. However, detailed information regarding the static and dynamic accuracy of these monitors is rarely available. Collaboration between scientists, clinicians, and manufacturers is essential to establish improved technical standards and protocols for testing of equipment and for the development of more reliable neonatal pulmonary monitors. The aim of this study was to develop a protocol for the in vitro assessment of commercial infant pulmonary function equipment which could be applied within the laboratory to provide rapid feedback to the manufacturer. A recently released neonatal pulmonary monitor, the Bicore CP100 (software version 3.3), was selected for the development of this protocol. The deadspace and resistance of the measuring device were determined. The flow and airway pressure measuring systems were evaluated alone and connected to a tracheal tube for both static accuracy and frequency response. The pressure— volume relationship of the esophageal balloon was determined and its static accuracy and frequency response were assessed. The algorithms for on-line calculations were checked and their correct application confirmed by examination of an ASCII data print out. Finally, the pulmonary monitor was tested during intermittent positive pressure ventilation of a neonatal lung model of known compliance and resistance.Keywords
This publication has 19 references indexed in Scilit:
- The effects of bedside pulmonary mechanics testing during infant mechanical ventilation: A retrospective analysisPediatric Pulmonology, 1993
- A simplified method for determining the frequency response of pneumotachographs used in infantsPediatric Pulmonology, 1993
- Esophageal pressure manometry in human infantsPediatric Pulmonology, 1991
- A very low dead space pneumotachograph for ventilatory measurements in newbornsJournal of Applied Physiology, 1990
- Measurement of pulmonary mechanics in the newborn lamb: a comparison of three techniquesJournal of Applied Physiology, 1988
- Evaluation of neonatal pulmonary mechanics and energetics: A two factor least mean square analysisPediatric Pulmonology, 1988
- Identifying lung overdistention during mechanical ventilation by using volume‐pressure loopsPediatric Pulmonology, 1988
- Standardization of Spirometry—1987 UpdateAmerican Review of Respiratory Disease, 1987
- Automation of Pulmonary Function EquipmentChest, 1986
- Evaluation of the lung ventilator performance analyserAnaesthesia, 1976