Absolute Cerebral Blood Flow and Blood Volume Measured by Magnetic Resonance Imaging Bolus Tracking: Comparison with Positron Emission Tomography Values
Open Access
- 1 April 1998
- journal article
- research article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 18 (4) , 425-432
- https://doi.org/10.1097/00004647-199804000-00011
Abstract
The authors determined cerebral blood flow (CBF) with magnetic resonance imaging (MRI) of contrast agent bolus passage and compared the results with those obtained by O-15 labeled water (H215O) and positron emission tomography (PET). Six pigs were examined by MRI and PET under normo- and hypercapnic conditions. After dose normalization and introduction of an empirical constant ΦGd, absolute regional CBF was calculated from MRI. The spatial resolution and the signal-to-noise ratio of CBF measurements by MRI were better than by the H215O-PET protocol. Magnetic resonance imaging cerebral blood volume (CBV) estimates obtained using this normalization constant correlated well with values obtained by O-15 labeled carbonmonooxide (C15O) PET. However, PET CBV values were approximately 2.5 times larger than absolute MRI CBV values, supporting the hypothesized sensitivity of MRI to small vessels.Keywords
This publication has 15 references indexed in Scilit:
- Hyperacute stroke: evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging.Radiology, 1996
- Dynamic Penumbra Demonstrated by Sequential Multitracer PET after Middle Cerebral Artery Occlusion in CatsJournal of Cerebral Blood Flow & Metabolism, 1994
- Microscopic susceptibility variation and transverse relaxation: Theory and experimentMagnetic Resonance in Medicine, 1994
- Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings.Radiology, 1994
- Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?Magnetic Resonance in Medicine, 1993
- Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effectsMagnetic Resonance in Medicine, 1988
- Cerebral Transit of an Intravascular Tracer May Allow Measurement of Regional Blood Volume but Not Regional Blood FlowJournal of Cerebral Blood Flow & Metabolism, 1984
- In vivo Measurement of Regional Cerebral Haematocrit Using Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1984
- The Effects of Changes in Pa CO 2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit TimeStroke, 1974
- Researches on the Circulation Time in Organs and on the Influences which affect itThe Journal of Physiology, 1893