Pulse oximetry in ventilated preterm newborns: reliability of detection of hyperoxaemia and hypoxaemia, and feasibility of alarm settings
- 1 June 1995
- journal article
- Published by Wiley in Acta Paediatrica
- Vol. 84 (6) , 613-617
- https://doi.org/10.1111/j.1651-2227.1995.tb13709.x
Abstract
The aim of our study was to evaluate the reliability of pulse oximetry in detecting both hyper‐ and hypoxaemic states and to create clinically feasible alarm limits. A total of 792 readings of a pulse oximeter and corresponding values of arterial oxygen tension from 146 (79M, 67F) artificially ventilated preterm newborns with indwelling umbilical artery catheters were compared. Predictive value analysis of pulse oximeter readings related to arterial oxygen tension confirmed the ability of the pulse oximeter to identify both hypoxaemia and hyperoxaemia. However, a clinically feasible and safe range of alarm limits for maintenance of arterial oxygen tension of 40‐90 mmHg (5.3‐12kPa) could only be established at a sensitivity level less than 0.9. At a level of 0.85, the alarm range on the pulse oximeter was 92.5‐95%. Based on these findings, we are concerned about using pulse oximetry as the sole means of oxygen monitoring for preterm infants receiving supplementary oxygen. A combination of the pulse oximetry with other methods of blood‐gas monitoring seems mandatoryKeywords
This publication has 20 references indexed in Scilit:
- Arterial oxygen saturation in preterm neonates without respiratory failureThe Journal of Pediatrics, 1993
- Reliability of a pulse oximeter in the detection of hyperoxemiaThe Journal of Pediatrics, 1993
- Monitoring oxygen in the newborn: saturation or partial pressure?Archives of Disease in Childhood, 1987
- Pulse oximetry in preterm infants.Archives of Disease in Childhood, 1987
- Pulse oximetry for continuous oxygen monitoring in sick newborn infantsThe Journal of Pediatrics, 1986
- Transcutaneous monitoring of oxygenation: What is normal?The Journal of Pediatrics, 1986
- Transcutaneous oxygen and carbon dioxide monitoring in intensive care.Archives of Disease in Childhood, 1985
- Pulse oximetry in pediatric intensive care: Comparison with measured saturations and transcutaneous oxygen tensionThe Journal of Pediatrics, 1985
- Noninvasive arterial hemoglobin oxygen saturation versus transcutaneous oxygen tension monitoring in the preterm infantCritical Care Medicine, 1984
- Clinical implications of the oxyhemoglobin dissociation curve in the neonatal periodCritical Care Medicine, 1979