Chip PCR. I. Surface passivation of microfabricated silicon-glass chips for PCR
- 15 January 1996
- journal article
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 24 (2) , 375-379
- https://doi.org/10.1093/nar/24.2.375
Abstract
The microreaction volumes of PCR chips (a microfabricated silicon chip bonded to a piece of flat glass to form a PCR reaction chamber) create a relatively high surface to volume ratio that increases the significance of the surface chemistry in the polymerase chain reaction (PCR). We investigated several surface passivations in an attempt to identify 'PCR friendly' surfaces and used those surfaces to obtain amplifications comparable with those obtained in conventional PCR amplification systems using polyethylene tubes. Surface passivations by a silanization procedure followed by a coating of a selected protein or polynucleotide and the deposition of a nitride or oxide layer onto the silicon surface were investigated. Native silicon was found to be an inhibitor of PCR and amplification in an untreated PCR chip (i.e. native slicon) had a high failure rate. A silicon nitride (Si(3)N(4) reaction surface also resulted in consistent inhibition of PCR. Passivating the PCR chip using a silanizing agent followed by a polymer treatment resulted in good amplification. However, amplification yields were inconsistent and were not always comparable with PCR in a conventional tube. An oxidized silicon (SiO(2) surface gave consistent amplifications comparable with reactions performed in a conventional PCR tube.Keywords
This publication has 15 references indexed in Scilit:
- Chip PCR. II. Investigation of different PCR amplification systems in microbabricated silicon-glass chipsNucleic Acids Research, 1996
- Rationale for cost-effective laboratory medicineClinical Microbiology Reviews, 1994
- Manipulation and flow of biological fluids in straight channels micromachined in siliconClinical Chemistry, 1994
- Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a ChipScience, 1993
- Required technology breakthroughs to assume widely accepted biosensorsApplied Biochemistry and Biotechnology, 1993
- Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzerClinical Chemistry, 1993
- Improvement in 'stat' laboratory turnaround time. A model continuous quality improvement project.1992
- Microfabrication Techniques for Integrated Sensors and MicrosystemsScience, 1991
- Molecular Self-Assembly and Nanochemistry: a Chemical Strategy for the Synthesis of NanostructuresScience, 1991
- Light-Directed, Spatially Addressable Parallel Chemical SynthesisScience, 1991