Comparison of ionization chambers of various volumes for IMRT absolute dose verification
- 10 January 2003
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 30 (2) , 119-123
- https://doi.org/10.1118/1.1536161
Abstract
IMRT plans are usually verified by phantom measurements: dose distributions are measured using film and the absolute dose using an ionization chamber. The measured and calculated doses are compared and planned MUs are modified if necessary. To achieve a conformal dose distribution, IMRT fields are composed of small subfields, or "beamlets." The size of beamlets is on the order of 1 x 1 cm2. Therefore, small chambers with sensitive volumes < or = 0.1 cm3 are generally used for absolute dose verification. A dosimetry system consisting of an electrometer, an ion chamber, and connecting cables may exhibit charge leakage. Since chamber sensitivity is proportional to volume, the effect of leakage on the measured charge is relatively greater for small chambers. Furthermore, the charge contribution from beamlets located at significant distances from the point of measurement may be below the small chambers threshold and hence not detected. On the other hand, large (0.6 cm3) chambers used for the dosimetry of conventional external fields are quite sensitive. Since these chambers are long, the electron fluence through them may not be uniform ("temporal" uniformity may not exist in the chamber volume). However, the cumulative, or "spatial" fluence distribution (as indicated by calculated IMRT dose distribution) may become uniform at the chamber location when the delivery of all IMRT fields is completed. Under the condition of "spatial" fluence uniformity, the charge collected by the large chamber may accurately represent the absolute dose delivered by IMRT to the point of measurement. In this work, 0.6, 0.125, and 0.009 cm3 chambers were used for the absolute dose verification for tomographic and step-and-shoot IMRT plans. With the largest, 0.6 cm3 chamber, the measured dose was equal to calculated within 0.5%, when no leakage corrections were made. Without leakage corrections, the error of measurement with a 0.125 cm3 chamber was 2.6% (tomographic IMRT) and 1.5% (step-and-shoot IMRT). When doses measured by a 0.125 cm3 chamber were corrected for leakage, the difference between the calculated and measured doses reduced to 0.5%. Leakage corrected doses obtained with the 0.009 cm3 chamber were within 1.5%-1.7% of calculated doses. Without leakage corrections, the measurement error was 16% (tomographic IMRT) and 7% (step-and-shoot IMRT).Keywords
This publication has 10 references indexed in Scilit:
- Reduction of cardiac and lung complication probabilities after breast irradiation using conformal radiotherapy with or without intensity modulationRadiotherapy and Oncology, 2002
- A treatment planning comparison of 3D conformal therapy, intensity modulated photon therapy and proton therapy for treatment of advanced head and neck tumoursRadiotherapy and Oncology, 2001
- Improvement of tomographic intensity modulated radiotherapy dose distributions using periodic shifting of arc abutment regionsMedical Physics, 2000
- Relative profile and dose verification of intensity-modulated radiation therapyInternational Journal of Radiation Oncology*Biology*Physics, 2000
- Clinical delivery of intensity modulated conformal radiotherapy for relapsed or second-primary head and neck cancer using a multileaf collimator with dynamic controlRadiotherapy and Oncology, 1999
- Quantitative dosimetric verification of an IMRT planning and delivery systemRadiotherapy and Oncology, 1998
- Quality assurance of serial tomotherapy for head and neck patient treatmentsInternational Journal of Radiation Oncology*Biology*Physics, 1998
- Dosimetric Verification of the Dynamic Intensity-Modulated Radiation Therapy of 92 PatientsInternational Journal of Radiation Oncology*Biology*Physics, 1998
- Phantoms for IMRT Dose Distribution Measurement and Treatment VerificationInternational Journal of Radiation Oncology*Biology*Physics, 1998
- Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck regionInternational Journal of Radiation Oncology*Biology*Physics, 1997