Temperature control in Lowicryl K4M and glycol methacrylate during polymerization: is there a low‐temperature embedding method?
- 1 November 1986
- journal article
- research article
- Published by Wiley in Journal of Microscopy
- Vol. 144 (2) , 107-126
- https://doi.org/10.1111/j.1365-2818.1986.tb02793.x
Abstract
SUMMARY: An apparatus for embedding tissues at resin temperatures down to 228 K is described. By placing thermocouples in the resin the temperature has been monitored during embedding at low temperature with glycol methacrylate (GMA) and Lowicryl K4M. Even in this apparatus with a liquid cooling bath the heat of polymerization is not dissipated and the resin temperature rises. This rise is directly proportional to the resin temperature at the onset of polymerization and is higher in Lowicryl K4M than GMA. The initial resin temperature also affects the time taken for polymerization. The time to the onset of the peak and its duration are both increased as the temperature is lowered. This effect is more pronounced with GMA than Lowicryl K4M and polymerization of GMA is inhibited at the lowest temperature used. When Lowicryl K4M, polymerized at low temperature, is warmed up to ambient a further exothermic reaction occurs, which causes the resin temperature to rise well above ambient. Both this temperature peak and that during polymerization are reduced, but not totally eliminated, by reducing the resin volume. Aircooled systems are inefficient compared with the low‐temperature apparatus used here and the resin temperature rise is consequently greater and, even with small resin volumes, it can be very high. It is therefore unlikely for published methods that the temperature specified has been maintained in the resin during polymerization. The implications of these findings are discussed in relation to enzyme and antigen survival. Recommendations include use of very small volumes of resin, refrigerated liquid‐bath rather than air‐cooled systems and contact with a heat sink when specimens are warmed up to ambient temperature. Examples of enzyme reaction, antigen survival and structural preservation obtained with the method are presented.Keywords
This publication has 30 references indexed in Scilit:
- Glycol methacrylate embedding in histotechnology: factors which influence the evolution of heat during polymerization at room temperatureJournal of Microscopy, 1985
- Periodate-acid treatment of sections permits on-grid immunogold localization of pea seed vicilin in ER and GolgiProtoplasma, 1984
- A simple post-embedding system for the rapid demonstration of tissue antigens under the electron microscopeJournal of Molecular Histology, 1983
- Ultrastructural localization of antigenic sites on osmium-fixed tissues applying the protein A-gold technique.Journal of Histochemistry & Cytochemistry, 1983
- Specimen preparation for electron microscopy using low temperature embedding resinsJournal of Microscopy, 1982
- The problems of preserving molecular structure of cellular components in connection with electron microscopic analysisJournal of Ultrastructure Research, 1976
- Protein crystallography at sub-zero temperatures: Lysozyme-substrate complexes in cooled mixed solventsJournal of Molecular Biology, 1975
- Histochemical localization of ?-glycosidases in roots ofZea maysProtoplasma, 1973
- A new model for mitochondrial membranes based on structural and on biochemical informationJournal of Ultrastructure Research, 1970
- Recent modifications of the glycol methacrylate embedding procedureJournal of Ultrastructure Research, 1967