Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for obstructive sleep apnoea
Open Access
- 1 March 2006
- Vol. 61 (3) , 226-231
- https://doi.org/10.1136/thx.2005.046300
Abstract
Background: The simplest method of initiating and maintaining therapeutic continuous positive airways pressure (CPAP) therapy for obstructive sleep apnoea (OSA) has not been established. Methods: Ninety eight subjects with OSA requiring CPAP treatment (more than 10 dips in oxygen desaturation of >4% per hour of sleep study and Epworth Sleepiness Score (ESS) >9) were randomised prospectively to three different methods of CPAP delivery for 6 months: (1) autotitration pressure throughout; (2) autotitration pressure for 1 week followed by fixed pressure (95th centile) thereafter; and (3) fixed pressure determined by algorithm (based on neck size and dip rate). Patients and investigators were blind to group allocation. One week after initiation the patients were routinely reviewed by sleep nurses. Study assessments took place before starting CPAP treatment and 1 and 6 months after to assess ESS, maintenance of wakefulness test, 24 hour blood pressure, general health (SF-36), and sleep apnoea related quality of life. CPAP internal monitoring data were also collected. Results: There were no significant differences in any of the outcome measures or CPAP monitoring data between the three groups. The 95th centile CPAP pressures delivered in the 6 month and 1 week autotitration groups were higher than in the algorithm group, but the median pressures were lowest in the 6 month autotitration group. Conclusions: The method of determining CPAP pressure for treatment of moderate to severe OSA makes no significant difference to clinical outcome measures. The autotitration CPAP machine used has no advantage in this setting over simpler methods of pressure determination.Keywords
This publication has 27 references indexed in Scilit:
- Comparison of the maintenance of wakefulness test (MWT) to a modified behavioral test (OSLER) in the evaluation of daytime sleepinessJournal of Sleep Research, 2004
- Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised prospective parallel trialThe Lancet, 1999
- Sleep Fragmentation Indices as Predictors of Daytime Sleepiness and nCPAP Response in Obstructive Sleep ApneaAmerican Journal of Respiratory and Critical Care Medicine, 1998
- Development of a Disease-specific Health-related Quality of Life Questionnaire for Sleep ApneaAmerican Journal of Respiratory and Critical Care Medicine, 1998
- Randomised placebo controlled trial of daytime function after continuous positive airway pressure (CPAP) therapy for the sleep apnoea/hypopnoea syndromeThorax, 1998
- Use of Conventional and Self-Adjusting Nasal Continuous Positive Airway Pressure for Treatment of Severe Obstructive Sleep Apnea SyndromeChest, 1998
- Comparison of three measures of quality of life outcome in the evaluation of continuous positive airways pressure therapy for sleep apnoeaJournal of Sleep Research, 1997
- A behavioural test to assess daytime sleepiness in obstructive sleep apnoeaJournal of Sleep Research, 1997
- Automatic nasal continuous positive airway pressure titration in the laboratory: patient outcomesThorax, 1997
- Predicting nasal continuous positive airway pressure.American Journal of Respiratory and Critical Care Medicine, 1994