Isolation of large peptides derived by cyanogen bromide cleavage of thermolysin using fast protein liquid chromatography (FPLC)
- 1 August 1984
- journal article
- research article
- Published by Wiley in International Journal of Peptide and Protein Research
- Vol. 24 (2) , 104-111
- https://doi.org/10.1111/j.1399-3011.1984.tb00934.x
Abstract
The recently introduced fast protein liquid chromatography (FPLC) system of Pharmacia (Uppsala, Sweden) was employed to isolate rather large peptides derived from thermolysin by selective chemical fragmentation at methionine in positions 120 and 205 of the polypeptide chain of 316 amino acid residues. Thermolysin was cleaved under conditions of limited fragmentation in order to produce, besides fragments 1-120, 121-205 and 206-316, the overlapping fragments 1-205 and 121-316. These polypeptides were separated employing prepacked Mono Q or Mono S columns (quaternary ammonium and sulfonic acid support, respectively). The columns were equilibrated with acetate-7 M urea buffer, pH 5.0 or 6.0 and eluted with a gradient of sodium chloride or acetate. Separations were achieved in 10-20 min and were carried out also at a semipreparative level (1-3 mg per run). All 5 protein fragments were isolated in homogeneous form, as judged by amino acid analysis and electrophoresis. Considering that protein fragmentation with cyanogen bromide is the most commonly used procedure to achieve selective chemical fragmentation of a polypeptide chain, these results indicate that FPLC with ionic exchangers can be usefully employed to isolate rather large protein fragments especially suitable for automatic sequence analysis with the sequenator. [Implications with respect to the use of FPLC to sequence human protein molecules in the clinical laboratory setting are presented.].Keywords
This publication has 23 references indexed in Scilit:
- Domain characteristics of the cyanogen bromide fragment 121–316 of thermolysinInternational Journal of Peptide and Protein Research, 1983
- Domain characteristics of the carboxyl‐terminal fragment 206–316 of thermolysinBiopolymers, 1983
- Ion-exchange and straight-phase partition high-performance liquid chromatography of the opiates on silicaJournal of Chromatography A, 1981
- Advances in Protein SequencingAnnual Review of Biochemistry, 1981
- Effects of Flow Rate and Eluant Composition on the High Performance Liquid Chromatography of ProteinsJournal of Liquid Chromatography, 1980
- Conformational and immunochemical analysis of the cyanogen bromide fragments of thermolysinBiochemistry, 1979
- Use of Trialkyl Ammonium Phosphate (TAAP) Buffers in Reverse Phase HPLC for High Resolution and High Recovery of Peptides and ProteinsJournal of Liquid Chromatography, 1978
- High speed ion exchange chromatography of proteinsAnalytical Chemistry, 1976
- Determination of the amino acid sequence of porcine trypsin by sequenator analysisBiochemistry, 1973
- Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4Nature, 1970