Experimental Evaluation of the Nukiyama-Tanasawa Equation for Pneumatically Generated Aerosols Used in Flame Atomic Spectrometry
- 1 April 1992
- journal article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 46 (4) , 669-676
- https://doi.org/10.1366/0003702924125014
Abstract
The Nukiyama-Tanasawa equation has been checked for its applicability to predict the Sauter mean diameter of aerosols generated pneumatically under the conditions usually employed in FAAS. The measurements of droplet-size distribution have been carried out by means of a laser Fraunhofer diffraction system. The effects of both gas and liquid flows, and solvent physical properties, on experimental and calculated Sauter mean diameters of the aerosols have been studied. The results show that this equation, under normal conditions used in FAAS, correctly describes the trends of Sauter mean diameter variation of aerosols generated pneumatically with respect to the flows of nebulizing gas and liquid. Increases in liquid flow or decreases in gas flow give rise to increases in Sauter mean diameters of the aerosols. However, the absolute values predicted according to the equation far exceed the experimental Sauter mean diameters obtained, the divergences being larger at higher liquid flow/nebulizing gas flow ratios. The overestimation for water ranged from 1.8- to 8.1-fold, and for organic solvents and methanol+water mixtures from 3.6- to 13.3-fold. Under the conditions studied, experimental Sauter mean diameter values for the organic solvents and methanol+water mixtures studied were well below those found for water, under comparable conditions. This result contradicts the predictions of the Nukiyama-Tanasawa equation mainly at high liquid flow/nebulizing gas flow ratios. The main reason for this divergence is the overweighting assigned to the second term of the equation.Keywords
This publication has 19 references indexed in Scilit:
- Influence of solvent physical properties on drop size distribution, transport and sensitivity in flame atomic absorption spectrometry with pneumatic nebulizationJournal of Analytical Atomic Spectrometry, 1991
- Evolution of drop size distributions for pneumatically generated aerosols in inductively coupled plasma-atomic emission spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1990
- Effect of droplet size on the phosphine depression of calcium atomic emission signals in flame spectrometryAnalytica Chimica Acta, 1985
- Surface tension effects on aerosol properties in atomic spectrometryAnalytical Chemistry, 1984
- Influence of aerosol drop size on signals and interferences in flame atomic absorption spectrometryAnalytical Chemistry, 1984
- Sample Introduction: The Achilles' Heel of Atomic Spectroscopy?Analytical Chemistry, 1984
- Prediction of nebulizer characteristics for concentric nebulizer systems with a mathematical modelAnalytical Chemistry, 1984
- A review of the theory of flow processes of compressible and incompressible media in nebulizersSpectrochimica Acta Part B: Atomic Spectroscopy, 1983
- Mathematical model for concentric nebulizer systemsAnalytical Chemistry, 1983
- Characterization of droplet sprays produced by pneumatic nebulizersAnalytical Chemistry, 1980