Quantification of raf antisense oligonucleotide (rafAON) in biological matrices by LC-MS/MS to support pharmacokinetics of a liposome-entrapped rafAON formulation
- 30 December 2004
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 19 (4) , 272-278
- https://doi.org/10.1002/bmc.450
Abstract
An LC-MS/MS method was developed to quantify an antisense oligonucleotide against Raf-1 expression (rafAON) in monkey and mouse plasma and in mouse tissue homogenates from animals dosed with a liposome-entrapped rafAON easy-to-use formulation (LErafAON-ETU) intended for use as an antineoplastic agent. RafAON was extracted from mouse and monkey plasma using solid-phase extraction. Tissues were homogenized and sample cleanup was achieved by protein precipitation. RafAON and the internal standard (IS) were separated on a Hamilton PRP-1 column and quantified by tandem mass spectrometry using an electrospray source in negative ion mode. The total run time was 4.0 min. The peak areas of two rafAON transitions were summed and plotted against the peak area of an IS transition to generate the standard curve. In monkey plasma the linear range was 50–10,000 ng/mL, and in mouse plasma it was 25–5000 ng/mL. The lower limit of quantification was 500 ng/mL (10 µg/g tissue) in heart, kidney, liver, lung and spleen homogenates, and the standard curve was linear up to 10,000 ng/mL. Accuracy, precision and stability were evaluated and found to be acceptable in all three matrices. The assay was used to support pharmacokinetics and tissue distribution studies of LErafAON-ETU in mice and monkeys. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 22 references indexed in Scilit:
- Mass Spectrometry and Enzyme-Linked Immunosorbent Assay Methods for the Quantitation of Liposomal Antisense Oligonucleotide (LE-rafAON) in Human PlasmaPublished by Elsevier ,2004
- Liposome-Mediated Delivery of Oligodeoxynucleotides In VivoDrug Delivery, 2002
- Real-Time Monitoring of the Hybridization Reaction: Application to the Quantification of Oligonucleotides in Biological SamplesBiochemical and Biophysical Research Communications, 2000
- A Nonradioisotope Biomedical Assay for Intact Oligonucleotide and Its Chain-Shortened Metabolites Used for Determination of Exposure and Elimination Half-Life of Antisense Drugs in TissueAnalytical Biochemistry, 1999
- The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compoundsRapid Communications in Mass Spectrometry, 1999
- Toxicity and immunomodulatory activity of liposomal vectors formulated with cationic lipids toward immune effector cellsPublished by Elsevier ,1998
- A competitive enzyme hybridization assay for plasma determination of phosphodiester and phosphorothioate antisense oligonucleotidesNucleic Acids Research, 1997
- Rapid Measurement of Modified Oligonucleotide Levels in Plasma Samples with a Fluorophore Specific for Single-Stranded DNAAntisense and Nucleic Acid Drug Development, 1997
- Various factors influencing the signal intensity of oligonucleotides in electrospray mass spectrometryJournal of Mass Spectrometry, 1994
- Quantitative analysis of phosphorothioate oligonucleotides in biological fluids using fast anion-exchange chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1993