Ex vivo and in vitro platelet adhesion on RFGD deposited polymers
- 1 March 1992
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 26 (3) , 357-372
- https://doi.org/10.1002/jbm.820260307
Abstract
Clinical applications of small‐diameter synthetic vascular grafts are hindered by their highly thrombogenic surfaces. To develop vascular grafts that resist thrombotic occlusion, a radio frequency glow discharge (RFGD) process was employed to modify the surface of existing graft materials. Ultrathin coatings of RFGD polymers of ethylene (E), tetrafluoroethylene (TFE), and hexamethyldisiloxane (HMDS) were deposited on the lumen of Dacron grafts. Surfaces were characterized by electron spectroscopy for chemical analysis (ESCA). The effect of glow discharge treatments on plateletgraft interactions was evaluated in an ex vivo baboon shunt model. Following placement of an untreated or RFGD‐ treated graft in the shunt, deposition of 111Indium‐labeled platelets was monitored for 60 min by γ camera imaging. Untreated Dacron rapidly accumulated large numbers of platelets, reaching a plateau i n 60 min. HMDS‐ and TFE‐treated Dacron had significantly lower levels of platelet deposition compared to the untreated control. In contrast, the ethylene treatment of Dacron augmented platelet deposition, making it the most platelet‐ adherent surface studied. In vitro studies were also performed using untreated and RFGD‐treated poly (ethylene terephthalate) (PET) coverslips. ESCA verified that the surface composition of the untreated and RFGD‐treated coverslips were virtually identical to their untreated and treated Dacron graft counterparts. Samples were incubated in washed baboon platelet suspensions for 2 h at 37°C. Platelet adhesion on the untreated PET was relatively high, and many of the platelets had a completely spread morphology. The HMDS and TFE treatment of PET reduced the number of adherent platelets and prevented platelet spreading on the surface. Platelet adhesion and spreading on the ethylene‐treated surface was the highest among the four studied. There is a remarkable linear correlation of the ex vivo and in vitro platelet adhesion data.Keywords
This publication has 19 references indexed in Scilit:
- Antibody Immobilization onto Glow Discharge Treated PolymersBiotechnology Progress, 1991
- The structure of organosilicon plasma‐polymerized coatings on metal substratesJournal of Applied Polymer Science, 1989
- The platelet reactivity of vascular graft prostheses: an in vitro model to test the effect of preclottingBiomaterials, 1986
- The Importance of Vascular Graft Surface Composition as Demonstrated by a New Gas Discharge Treatment for Small Diameter GraftsPublished by ASTM International ,1986
- Comparison of the thrombogenicity of four types of knitted Dacron arterial graft in an artificial circulationBiomaterials, 1985
- In vivo quantitation of platelet deposition on human peripheral arterial bypass grafts using indium-111-labeled plateletsThe American Journal of Cardiology, 1983
- Evaluation of plasma polymerized hexamethylcyclotrisiloxane biomaterials towards adhesion of canine platelets and leucocytesBiomaterials, 1981
- Plasma polymerization. III. An ESCA investigation of polymers synthesized by excitation of inductively coupled RF plasmas in perfluorocyclohexa‐1,3‐ and 1,4‐dienes, and in perfluorocyclohexeneJournal of Polymer Science: Polymer Chemistry Edition, 1980
- Plasma polymerization of tetrafluoroethylene. I. Inductive radio frequency dischargeJournal of Applied Polymer Science, 1979
- Use of Plasma Polymerization for Preparing Silicone‐Coated Membranes for Possible Use in Blood OxygenatorsArtificial Organs, 1979