Phase‐sensitive inversion recovery for detecting myocardial infarction using gadolinium‐delayed hyperenhancement†
Top Cited Papers
Open Access
- 23 January 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (2) , 372-383
- https://doi.org/10.1002/mrm.10051
Abstract
After administration of gadolinium, infarcted myocardium exhibits delayed hyperenhancement and can be imaged using an inversion recovery (IR) sequence. The performance of such a method when using magnitude‐reconstructed images is highly sensitive to the inversion recovery time (TI) selected. Using phase‐sensitive reconstruction, it is possible to use a nominal value of TI, eliminate several breath‐holds otherwise needed to find the precise null time for normal myocardium, and achieve a consistent contrast. Phase‐sensitive detection is used to remove the background phase while preserving the sign of the desired magnetization during IR. Experimental results are presented which demonstrate the benefits of both phase‐sensitive IR image reconstruction and surface coil intensity normalization for detecting myocardial infarction (MI). The phase‐sensitive reconstruction method reduces the variation in apparent infarct size that is observed in the magnitude images as TI is changed. Phase‐sensitive detection also has the advantage of decreasing the sensitivity to changes in tissue T1 with increasing delay from contrast agent injection. Magn Reson Med 47:372–383, 2002. Published 2002 Wiley‐Liss, Inc.Keywords
This publication has 26 references indexed in Scilit:
- The Use of Contrast-Enhanced Magnetic Resonance Imaging to Identify Reversible Myocardial DysfunctionNew England Journal of Medicine, 2000
- Inversion recovery image reconstruction with multiseed region-growing spin reversalJournal of Magnetic Resonance Imaging, 1996
- Intensity correction of phased‐array surface coil imagesMagnetic Resonance in Medicine, 1996
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991
- A simple method for the restoration of signal polarity in multi‐image inversion recovery sequences for measuring T1Magnetic Resonance in Medicine, 1991
- Regional phase correction of inversion‐recovery MR imagesMagnetic Resonance in Medicine, 1990
- The correction of nonuniform signal intensity profiles in magnetic resonance imagingJournal of Digital Imaging, 1989
- Intensity correction in surface-coil MR imagingAmerican Journal of Roentgenology, 1987
- Real‐value representation in inversion‐recovery NMR imaging by use of a phase‐correction methodMagnetic Resonance in Medicine, 1986
- Apparent changes of appearance of inversion‐recovery imagesMagnetic Resonance in Medicine, 1985