An Apparatus for Neutron Diffraction from Single Crystals

Abstract
The problem of coincidence reflections with a Bragg peak is discussed and an apparatus is described for an automatic averaging over the ``umweganregung'' and ``aufhellung'' peaks to come very close to the true Bragg intensity. Results of an experiment are considered to prove the validity of the method. A refrigerator arrangement is described for work below room temperature.