An Intraoperative Beta Probe Dedicated to Glioma Surgery: Design and Feasibility Study
- 12 February 2007
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 54 (1) , 30-41
- https://doi.org/10.1109/tns.2006.885574
Abstract
Surgery is considered as the primary therapeutic procedure for gliomas and several recent clinical studies have shown that total tumor resection is directly associated with longer survival when compared to subtotal resection. In order to refine the resection in the boundaries of gliomas, we are developing an intraoperative probe specifically dedicated to the localization of residual tumor labeled with positron emitters. The probe is designed to be compact and electrically safe in order to be directly coupled to the excision tool leading to simultaneous detection and removal of tumor tissues. It is built with clear and plastic scintillating fibers held in a closed packed annular arrangement ensheathing the excision tool. The annihilation gamma ray background is eliminated by a real-time subtraction method. Validation of the technical choice and optimization of the probe geometry were performed by preliminary measurements and Monte Carlo simulations based on the MCNP-4C code and an anthropomorphic brain phantom. The theoretical probe sensitivity was found to be 82 cps/muCi/ml with a gamma ray rejection efficiency of 99.6%. The expected minimum radiotracer detectable concentration for tumors labeled with 18 F-FET was 0.10 muCi/ml. When compared to the 0.29 muCi/ml average concentration in the bulk of the tumor, this result demonstrate the potential ability of the probe to define more accurately the extent of brain tumor resectionKeywords
This publication has 30 references indexed in Scilit:
- Update on detection of sentinel lymph nodes in patients with breast cancerSeminars in Nuclear Medicine, 2005
- Feasibility of a Beta-Gamma Digital Imaging Probe for Radioguided SurgeryIEEE Transactions on Nuclear Science, 2004
- Radio-guided brain tumorectomy using a gamma detecting probe and a mobile solid-state gamma cameraSurgical Neurology, 2004
- Primary brain tumours in adultsThe Lancet, 2003
- A solid-state intraoperative beta probe systemIEEE Transactions on Nuclear Science, 2000
- A miniature phoswich detector for gamma-ray localization and beta imagingIEEE Transactions on Nuclear Science, 1998
- Design considerations and initial performance of a 1.2 cm/sup 2/ beta imaging intra-operative probeIEEE Transactions on Nuclear Science, 1996
- Optimizing light collection from thin scintillators used in a beta-ray camera for surgical useIEEE Transactions on Nuclear Science, 1996
- Investigation of the physical aspects of beta imaging probes using scintillating fibers and visible light photon countersIEEE Transactions on Nuclear Science, 1995
- Comparison of in vivo scintillation probes and gamma cameras for detection of small, deep tumoursPhysics in Medicine & Biology, 1989