Neonatal Pulse Oximetry: Accuracy and Reliability
- 1 May 1989
- journal article
- research article
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 83 (5) , 717-722
- https://doi.org/10.1542/peds.83.5.717
Abstract
Pulse oximetry has gained widespread use in neonatal oxygen monitoring. However, because specific morbidity in neonates has been related to abnormal levels of oxygen partial pressure (Pao2), it is essential to demonstrate that pulse oxygen saturation values (Spo2) are highly accurate and reflect with precision the simultaneous Pao2. In this report, data is presented that describe the accuracy of the Ohmeda Biox 3700 pulse oximeter. Spo2 was highly correlated with arterial blood oxygen saturation (r = .99) measured on arterial (catheter) blood using a two-wavelength Radiometer OSM2 Hemoximeter. When compared with Pao2, Spo2 values of 92% ± 3% (mean ± range) excluded all of the measured Pao2 values less than 45 mm Hg and greater than 100 mm Hg. Spo2-tcPo2 (transcutaneous Po2) and Spo2-Pao2 (catheter or percutaneous arterial Po2) correlations showed that bronchopulmonary dysplasia, percutaneous arterial sampling, and nipple feeding skewed the tcPo2 but not the Pao2 correlations with Spo2, indicating that Spo2 is not sensitive to peripheral factors that affect tcPo2. Spo2-Pao2 correlation was not affected by gestational age. A high degree of accuracy of Spo2 values and Spo2 prediction of normal appearing Pao2 values are defined by these results.Keywords
This publication has 12 references indexed in Scilit:
- Pulse Oximetry Advantages in Infants With Bronchopulmonary DysplasiaPediatrics, 1986
- Transcutaneous monitoring of oxygenation: What is normal?The Journal of Pediatrics, 1986
- Underestimation of arterial oxygen tension by transcutaneous electrode with increasing age in infants.Archives of Disease in Childhood, 1985
- Pulse oximetry in pediatric intensive care: Comparison with measured saturations and transcutaneous oxygen tensionThe Journal of Pediatrics, 1985
- Limitations of Transcutaneous Po2 and Pco2 Monitoring in Infants with Bronchopulmonary DysplasiaPediatrics, 1984
- Redistribution of cardiac output and oxygen delivery in the hypoxemic fetal lambAmerican Journal of Obstetrics and Gynecology, 1979
- Blood flow to fetal organs as a function of arterial oxygen contentAmerican Journal of Obstetrics and Gynecology, 1979
- Oxygen toxicity in neonatal and adult animals of various speciesJournal of Applied Physiology, 1978
- TRANS-CUTANEOUS OXYGEN-TENSION IN SICK INFANTSPublished by Elsevier ,1978
- Respiratory Gases in the Regulation of the Pulmonary CirculationPhysiological Reviews, 1961