Results from the balloon ozone intercomparison campaign (BOIC)
- 20 November 1986
- journal article
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 91 (D12) , 13137-13152
- https://doi.org/10.1029/jd091id12p13137
Abstract
The purpose of the Balloon Ozone Intercomparison Campaign (BOIC) was to assess the accuracy and precision of various ozone measurement systems under development and those flown operationally. Ozone observations made by in situ UV absorption photometers from four groups, two solar UV absorption photometers, three varieties of electrochemical sondes, and a mass spectrometer were intercompared in three flight missions, each involving several balloon flights. Concurrent Umkehr and satellite observations were also intercompared. The National Bureau of Standards (NBS)provided a reference ozone source for intercomparing several of the in situ instruments at ground pressure. Harvard University and the University of Minnesota each developed a calibration facility after the BOIC flights which enabled a comparison of the flight in situ photometers under simulated stratospheric pressure and ozone concentrations. The following is a summary of results. The standard deviation of the sensitivities among 18 instruments tested about the NBS reference was 11%. These differences appear in flight at the lower altitudes, but they change at higher altitudes, indicating height dependent errors, particularly for the electrochemical sondes. Comparisons at the two laboratory facilities simulating stratospheric conditions indicated differences of about 2% at 3 mbar for two of the flight in situ photometers. Ozone values among four in situ UV photometers flown together had a standard deviation about the mean value of about ±3% from the tropopause to about 41 km. This is very close to the expected accuracy of these measurements and therefore is an excellent result. However, during float at 42 km the difference nearly doubled. Experiments performed during flight demonstrated that even near 40 km, wall losses in three UV photometers were less than 5%, which is consistent with the laboratory simulations. A comparison of a complement of electrochemical sondes yielded results that agreed with the mean of the in situ UV photometers to within 0–20%, depending on the sonde type and altitude. The electrochemical sondes gave systematically lower ozone values at pressures lower than 10 mbar (above 31 km). A comparison between an in situ UV and a solar absorption photometer indicated a 10% difference in the stratosphere, where the in situ measurement was lower. Comparisons of electrochemical sondes and Umkehr and Solar backscattered ultraviolet (SBUV) satellite observations showed agreement to within their error bars (stated to be about 5–10%). In two comparisons between in situ UV photometers and satellite measurements, a consistent difference occurred between 10 and 3 mbar (28–40 km), implying a possible bias between the measurement types. Intercomparisons among all the instruments in the troposphere showed 20–30% differences from the mean. A comparison of pressure measurements performed by several experimenters resulted in differences as high as ±15% from the average measurement.Keywords
This publication has 20 references indexed in Scilit:
- Improved rocket ozonesonde (ROCOZ-A) 1: Demonstration of precisionApplied Optics, 1985
- A new ozone standard: The vapor pressure of ozone at liquid argon temperaturesGeophysical Research Letters, 1985
- An In-Situ Multipass UV-Absorption Ozone Sensor Designed for Stratospheric ApplicationsPublished by Springer Nature ,1985
- Trends in Tropospheric Ozone ConcentrationPublished by Springer Nature ,1985
- Absorption Coefficients of Ozone for the Backscattered UV Instruments — SBUV, TOMS, and BUV- and for the Dobson InstrumentPublished by Springer Nature ,1985
- The Ultraviolet Cross-Sections of Ozone: I. The MeasurementsPublished by Springer Nature ,1985
- NASA-JSC measurements during “la campagne d'intercomparaison d'ozonometres”, Gap, France, June 1981Planetary and Space Science, 1983
- Ozone profile intercomparison based on simultaneous observations between 20 and 40 kmPlanetary and Space Science, 1983
- Six years of regular ozone soundings over SwitzerlandPure and Applied Geophysics, 1973
- The Oxford-Kew ozone sondeProceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences, 1960