New Computed Tomographic Signs of Aortoenteric Fistula
- 1 September 1984
- journal article
- case report
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 119 (9) , 1073-1075
- https://doi.org/10.1001/archsurg.1984.01390210069015
Abstract
• Successful preoperative diagnosis of aortoenteric fistula is often difficult. Clinical findings, roentgenography, angiography, and endoscopy have been used in diagnosis with only partial success. Newer techniques of gallium citrate Ga 67 scanning, ultrasonography, and computed tomographic (CT) scanning have been used in recent years to establish the diagnosis of aortic graft infection or aortoenteric fistula. In two cases, the CT scan clearly established the diagnosis of secondary aortoenteric fistula, as well as two previously unreported signs of aortoenteric fistula: intraluminal aortic gas and paraprosthetic extravasation of contrast medium. (Arch Surg 1984;119:1073-1075)Keywords
This publication has 7 references indexed in Scilit:
- Aortoduodenal fistula: Endoscopic diagnosisDigestive Diseases and Sciences, 1980
- A complicated case of aortoduodenal fistulaAbdominal Radiology, 1979
- Diagnosis of Aortic Graft InfectionRadiology, 1979
- Angiographic demonstration of gastrointestinal bleeding due to aorto-duodenal fistulaThe British Journal of Radiology, 1976
- Aortoenteric and paraprosthetic-enteric fistulas: radiologic findingsAmerican Journal of Roentgenology, 1976
- Aortoenteric and Paraprosthetic-Enteric FistulasArchives of Surgery, 1974
- Small bowel erosion by synthetic aortic graftsThe American Journal of Surgery, 1966