Perfusion quantification using Gaussian process deconvolution
Open Access
- 31 July 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (2) , 351-361
- https://doi.org/10.1002/mrm.10213
Abstract
The quantification of perfusion using dynamic susceptibility contrast MRI (DSC-MRI) requires deconvolution to obtain the residual impulse response function (IRF). In this work, a method using the Gaussian process for deconvolution (GPD) is proposed. The fact that the IRF is smooth is incorporated as a constraint in the method. The GPD method, which automatically estimates the noise level in each voxel, has the advantage that model parameters are optimized automatically. The GPD is compared to singular value decomposition (SVD) using a common threshold for the singular values, and to SVD using a threshold optimized according to the noise level in each voxel. The comparison is carried out using artificial data as well as data from healthy volunteers. It is shown that GPD is comparable to SVD with a variable optimized threshold when determining the maximum of the IRF, which is directly related to the perfusion. GPD provides a better estimate of the entire IRF. As the signal-to-noise ratio (SNR) increases or the time resolution of the measurements increases, GPD is shown to be superior to SVD. This is also found for large distribution volumes. Magn Reson Med 48:351–361, 2002.Keywords
This publication has 19 references indexed in Scilit:
- Determination of arterial input function using fuzzy clustering for quantification of cerebral blood flow with dynamic susceptibility contrast‐enhanced MR imagingJournal of Magnetic Resonance Imaging, 2001
- Methodology of brain perfusion imagingJournal of Magnetic Resonance Imaging, 2001
- Modeling the hemodynamic response in fMRI using smooth FIR filtersIEEE Transactions on Medical Imaging, 2000
- Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging TechniquesJournal of Cerebral Blood Flow & Metabolism, 1999
- Modeling Cerebral Blood Flow and Flow Heterogeneity from Magnetic Resonance Residue DataJournal of Cerebral Blood Flow & Metabolism, 1999
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Mr contrast due to intravascular magnetic susceptibility perturbationsMagnetic Resonance in Medicine, 1995
- Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging.Radiology, 1994
- In vivo quantification of the unidirectional influx constant for Gd‐DTPA diffusion across the myocardial capillaries with MR imagingJournal of Magnetic Resonance Imaging, 1994
- Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effectsMagnetic Resonance in Medicine, 1988