The Effect of Live Time in Components of a Positron Tomograph on Image Quantification
- 1 January 1987
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 34 (1) , 337-343
- https://doi.org/10.1109/TNS.1987.4337359
Abstract
The livetime of several PET systems has been characterized in terms of a paralysing time after each coincidence event. If part of the deadtime is due to light collection and position encoding in a crystal array, the system deadtime is a function of the singles-to-coincidence-count ratio which in turn depends on the object size and radioisotope distribution. In this case it is necessary to make an independent measurement of the detector livetime. Since both detectors must be "live" to record a coincidence event, the detector contribution to system livetime is more pronounced in tomographs using position encoding schemes. Since "dead" detectors cannot contribute random events, the randoms rate will be less if deadtime is caused by the detectors rather than by the coincidence circuit. After analysing the sources of lost events at each stage in the encoding process we propose that, rather than using empi rical estimates, hardware be used to compute these losses.Keywords
This publication has 10 references indexed in Scilit:
- Imaging Performance of a Dynamic Positron Emission Tomograph: Positome IIIpIEEE Transactions on Medical Imaging, 1986
- The Electronics for the Donner 600-Crystal Positron TomographIEEE Transactions on Nuclear Science, 1986
- Evemt Localization in a Continuous Scintillation Detector Using Digital ProcessingIEEE Transactions on Nuclear Science, 1986
- A Real Time Digital Coincidence Processor for Positron Emission TomographyIEEE Transactions on Nuclear Science, 1986
- Testing an Improved Scintillation Camera for PET and SPECTIEEE Transactions on Nuclear Science, 1986
- A Multicrystal Two Dimensional BGO Detector System for Positron Emission TomographyIEEE Transactions on Nuclear Science, 1986
- Dead time correction and counting statistics for positron tomographyPhysics in Medicine & Biology, 1985
- Evaluation of the Performance Characteristics of the PC 4600 Positron Emission TomographJournal of Computer Assisted Tomography, 1984
- Performance Study of Single-Slice Positron Emission Tomography Scanners by Monte Carlo TechniquesIEEE Transactions on Medical Imaging, 1983
- PERFORMANCE EVALUATION OF A POSITRON TOMOGRAPH DESIGNED FOR BRAIN IMAGINGJournal of Computer Assisted Tomography, 1983