Hickman Catheter Complications in Marrow Transplant Recipients
- 1 January 1986
- journal article
- Published by Wiley in Journal of Parenteral and Enteral Nutrition
- Vol. 10 (1) , 58-62
- https://doi.org/10.1177/014860718601000158
Abstract
The complications associated with the insertion and use of 95 single lumen and 312 double lumen Hickman right atrial catheters in 357 marrow transplant recipients were retrospectively analyzed. Three-hundred (84%) first inserted catheters were in place for a median of 93 days (range, 16-209) without complications and were removed electively. Thirty-nine (9.6%) of all catheters were removed for infections and 24 (5.9%) for mechanical complications. Ninety-five patients (26.6% ) had 111 episodes of septicemia involving 128 separate organisms and 25 patients had 25 episodes of localized catheter infection with 26 separate organisms. The most frequently isolated organism was coagulase-negative staphylococcus. Twelve of 24 removals due to mechanical complications were caused by accidental pulling of the catheter by the patient. (Journal of Parenteral and Enteral Nutrition 10:58-62, 1986)Keywords
This publication has 5 references indexed in Scilit:
- Hickman Catheter Infections in Patients With MalignanciesMedicine, 1984
- Allogeneic Marrow TransplantationCancer Investigation, 1984
- Experience with Double Lumen Right Atrial CathetersJournal of Parenteral and Enteral Nutrition, 1982
- Use of Hickman Right Atrial Catheter for Vascular Access in Marrow Transplant RecipientsArchives of Surgery, 1981
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958