Mean transit time for the assessment of myocardial perfusion by videodensitometry.
- 1 April 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 81 (4) , 1331-1340
- https://doi.org/10.1161/01.cir.81.4.1331
Abstract
The intrinsic limitations of coronary arteriography to predict the physiological effects of coronary obstructions are well known. Therefore, more direct assessments of the functional significance of coronary stenoses are becoming increasingly important. Study of contrast passage by electrocardiogram-triggered digital radiography has been proposed as a way of assessing changes in myocardial perfusion. The main problems in this approach are the limited time for motionless image acquisition, the potential alteration of vascular volume between different states, and the changing flow pattern induced by contrast agents. This has led to empiric substitution of mean transit time (Tmn) by other time parameters and to representation of vascular volume by maximal contrast intensity (Dmax). To avoid these problems, intact dogs were studied during almost motionless image acquisition of 20-25 consecutive paced heart beats obtained with synchronous radiographic pulses. In this way, unequivocal and reproducible determination of Tmn was possible. Constant and maximal vascular volume was created by continuous infusion of dipyridamole, and it was proved that coronary flow in this model was not influenced by contrast injections. Flow in the circumflex artery was measured by a ring mounted and calibrated Doppler probe. In each dog, flow in the circumflex artery was varied by a balloon occluder in 12 small steps (range, 0-174 +/- 42 ml/min). Inverse appearance time (1/Tapp), Dmax, Dmax/Tapp, inverse time of maximal intensity (1/Tmax), and 1/Tmn were calculated and the relations of these parameters to measured flow were investigated. Tmn proved to be the most reliable parameter for this purpose (r = 0.97 +/- 0.02; mean +/- SD), followed by Tmax (r = 0.93 +/- 0.04). Dmax failed to represent vascular volume but, in fact, showed a moderate correlation with flow (r = 0.78 +/- 0.22), as did Tapp (r = 0.64 +/- 0.18, 0.75 +/- 0.27, and 0.59 +/- 0.26 for the three definitions of Tapp used in this study). Dmax/Tapp correlated better with flow than either component separately. Our results indicate that the mean transit time calculated by videodensitometry can be used to accurately assess changes in myocardial perfusion strictly according to the original principles of indicator dilution theory.This publication has 28 references indexed in Scilit:
- Coronary blood flow velocity during percutaneous transluminal coronary angioplasty as a guide for assessment of the functional resultThe American Journal of Cardiology, 1988
- Normalization of coronary flow reserve by percutaneous transluminal coronary angioplastyThe American Journal of Cardiology, 1988
- Assessment of myocardial perfusion by videodensitometry in the canine modelJournal of the American College of Cardiology, 1987
- Quantitative evaluation of regional myocardial blood flow by videodensitometric analysis of digital subtraction coronary arteriography in humansJournal of the American College of Cardiology, 1986
- Effects of previous myocardial infarction on measurements of reactive hyperemia and the coronary vascular reserveJournal of the American College of Cardiology, 1986
- Abnormal coronary flow reserve and abnormal radionuclide exercise test results in patients with normal coronary angiogramsJournal of the American College of Cardiology, 1985
- Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterizationThe American Journal of Cardiology, 1985
- The concept of apparent cardiac arrest as a prerequisite for coronary digital subtraction angiographyJournal of the American College of Cardiology, 1984
- Criteria for successful coronary angioplasty as assessed by alterations in coronary vasodilatory reserveJournal of the American College of Cardiology, 1984
- Does Visual Interpretation of the Coronary Arteriogram Predict the Physiologic Importance of a Coronary Stenosis?New England Journal of Medicine, 1984