Computer‐Assisted three‐dimensional reconstruction of epithelial cells attached to percutaneous implants
- 1 March 1995
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 29 (3) , 371-379
- https://doi.org/10.1002/jbm.820290312
Abstract
It is generally accepted that cell shape plays a pivotal role in many aspects of cell behavior including proliferation, differentiation, and gene expression. Although previous reports have shown that implant‐surface topography can alter cell shape in vitro, in vivo evidence for such an effect is largely based on intuitive interpretation of two‐dimensional histological sections. The objective of this in vivo, study was to develop a method to reconstruct in three dimensions the shape of epithelial cells attached to smooth and micromachined implant surfaces. Titanium‐coated epoxy replicas of smooth and 10‐μm‐deep micromachined grooved surfaces were implanted percutaneously in the parietal of region of rats. After 7 days the implants and attached tissue were removed and processed for light and electron microscopy. One‐micrometer‐thick serial histological sections were used to trace and digitize cells and their nuclei into a Hewlett Packard computer. Three‐dimensional images were reconstructed and rotated to measure length, width, height, area, orientation index and the angle cells or nuclei formed with the long axis of the grooves (XY angle), and the angle cells or nuclei formed with the long axis of the implant (XZ angle). Epithelial cells attached to the smooth surfaces were found to be significantly (P, < .05) flatter and more spread than were the cells attached to the grooved surfaces. Cells on the smooth surfaces were aligned parallel with the long axis of the implant, whereas on the grooved surfaces cells were oriented obliquely with the implant. There was a strong correlation (r = 0.9) between measurements of parameters of cells and those of nuclei on the smooth surfaces, but little correlation was found for the cells and their nuclei on grooved surfaces. These measurements indicated that cell shape is altered by the topography of the implant surface in vivo, but that one cannot necessarily predict the shape of a cell from the shape of its nucleus. © 1995 John Wiley & Sons, Inc.Keywords
This publication has 17 references indexed in Scilit:
- New ideas in biomaterials science—a path to engineered biomaterialsJournal of Biomedical Materials Research, 1993
- Computer‐assisted realignment of light micrograph images from consecutive section series of cat cerebral cortexJournal of Microscopy, 1992
- Effects of a grooved titanium‐coated implant surface on epithelial cell behavior in vitro and in vivoJournal of Biomedical Materials Research, 1989
- A new method for aligning histological serial sections for three-dimensional reconstructionComputers and Biomedical Research, 1989
- The extracellular matrix and cell shapeTrends in Biochemical Sciences, 1986
- Three-dimensional reconstruction from serial sectionsComputers and Biomedical Research, 1986
- Commitment to expression of the metalloendopeptidases, collagenase and stromelysin: relationship of inducing events to changes in cytoskeletal architecture.The Journal of cell biology, 1986
- Cell shape-mediated growth control of lens epithelial cells grown in cultureExperimental Cell Research, 1981
- Role of cell shape in growth controlNature, 1978
- A new hypothesis of contact guidance in tissue cellsExperimental Cell Research, 1976