Improvement of brain single photon emission tomography (SPET) using transmission data acquisition in a four-head SPET scanner
- 1 January 1993
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 20 (1) , 32-38
- https://doi.org/10.1007/bf02261243
Abstract
Attenuation coefficient maps (μ-maps) are a useful way to compensate for non-uniform attenuation when performing single photon emission tomography (SPET). A new method was developed to record single photon transmission data and aμ-map for the brain was produced using a four-head SPET scanner. Transmission data were acquired by a gamma camera opposite to a flood radioactive source attached to one of four gamma cameras in the four-head SPET scanner. Attenuation correction was performed using the iterative expectation maximization algorithm and theμ-map. Phantom studies demonstrated that this method could reconstruct the distribution of radioactivity more accurately than conventional methods, even for a severely non-uniformμ-map, and could improve the quality of SPET images. Clinical application to technetium-99m hexamethylpropylene amine oxime (HMPAO) brain SPET also demonstrated the usefulness of this method. Thus, this method appears to be promising for improvement in the image quality and quantitative accuracy of brain SPET.Keywords
This publication has 25 references indexed in Scilit:
- Improved iterative image reconstruction with automatic noise artifact suppressionIEEE Transactions on Medical Imaging, 1992
- Technique for the use of standard outlines for attenuation correction and quantification in SPECTNuclear Medicine Communications, 1990
- Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a methodEuropean Journal of Nuclear Medicine and Molecular Imaging, 1990
- A technique for using CT images in attenuation correction and quantification in SPECTNuclear Medicine Communications, 1989
- Implementation of simultaneous attenuation and detector response correction in SPECTIEEE Transactions on Nuclear Science, 1988
- IMPROVED SPECT USING SIMULTANEOUS EMISSION AND TRANSMISSION TOMOGRAPHY1987
- A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT)European Journal of Nuclear Medicine and Molecular Imaging, 1987
- IMPROVED SPECT QUANTIFICATION USING COMPENSATION FOR SCATTERED PHOTONS1984
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979
- THE LUXURY-PERFUSION SYNDROME AND ITS POSSIBLE RELATION TO ACUTE METABOLIC ACIDOSIS LOCALISED WITHIN THE BRAINThe Lancet, 1966