Comparative performance of ion exchange and ion-paired reversed phase high performance liquid chromatography for the determination of nucleotides in biological samples
- 1 September 1991
- journal article
- research article
- Published by Wiley in Biomedical Chromatography
- Vol. 5 (5) , 207-211
- https://doi.org/10.1002/bmc.1130050506
Abstract
We have compared anion exchange chromatography on APS-Hypersil (4.6 x 100 mm) eluted with a phosphate gradient with reversed phase chromatography on ODS-Hypersil (4.6 x 100 mm) in the presence of either tetrabutylammonium (TBA) or triethylammonium (TEA) ions with a methanol gradient. The systems have been compared both for ease of operation and for their resolving power with standard mixtures and acid extracts of both normal red cells (RBC) and ischaemic tissues. The two chromatographic modes exhibited similar separating efficiencies for standard mixtures of nucleotides but retention times were most stable using reversed phase liquid chromatography (RPLC) with TEA. Anion exchange columns slowly lost ion exchange capacity but selectivity was unchanged. RPLC in the presence of TBA gave reproducibile capacity factors only when operated isocratically due to irreversible changes to the silica surface. For RBCs the RPLC with TEA and anion exchange systems resolved 17 and 15 peaks, respectively, and for the ischaemic samples 22 and 14 peaks, respectively. However, nucleosides and bases were also resolved by the ODS column causing chromatographic crowding and uncertain peak identification.Keywords
This publication has 19 references indexed in Scilit:
- Optimised Conditions for the Routine HPLC Separation of Nucleotides in Cell ExtractsAdvances in experimental medicine and biology, 1989
- Isocractic reversed-phase high-performance liquid chromatography of ribonucleotides, deoxynucleotides, cyclic nucleotides and deoxycyclic nucleotidesJournal of Chromatography A, 1989
- Extraction and measurement of myocardial nucleotides, nucleosides, and purine bases by high-performance liquid chromatographyAnalytical Biochemistry, 1988
- Red cell pyrimidine 5' nucleotidase deficiency: determination of nucleotidase activity and nucleotide content using HPLCClinica Chimica Acta; International Journal of Clinical Chemistry, 1988
- Comparison of high-performance ion-exchange and ion-pair liquid chromatographic methods for the separation of tumour cell nucleotidesJournal of Chromatography B: Biomedical Sciences and Applications, 1987
- Purification of micromolar quantities of nucleotide analogs by reverse-phase high-performance liquid chromatography using a volatile buffer at neutral pHAnalytical Biochemistry, 1984
- Separation of nucleotides by ion-pair, reversed-phase high-performance liquid chromatographyJournal of Chromatography A, 1983
- Analysis of the free nucleotide pools of mammalian tissues by high-pressure liquid chromatographyAnalytical Biochemistry, 1982
- Determination of adenine nucleotides and inosine in human myocard by ion-pair reversed-phase high-performance liquid chromatographyJournal of Chromatography A, 1982
- Reversed phase high performance liquid chromatographic separations of nucleotides in the presence of solvophobic ionsAnalytical Chemistry, 1977