Statistical error mapping for reliable quantitative T1 imaging
- 1 January 1996
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 6 (1) , 244-249
- https://doi.org/10.1002/jmri.1880060143
Abstract
We developed a statistically based error image for rapid appreciation of unreliable regions in quantitative water proton T1 images. The chi-squared error and coefficient of variation of the fitted parameter were used to estimate uncertainties in the goodness-of-fit to monoexponential T1 relaxation and the reliability of the calculated T1, respectively, for each pixel. Errors exceeding a statistical threshold based on a .1 acceptance criterion were displayed as a color-coded overlay on the T1 image. Error maps of quantitative T1 images from 31 healthy volunteers showed a characteristic error structure; few pixels within the parenchyma had excessive errors. Clinical cases with stroke and sickle cell disease showed deviations from the normal pattern in the spatial distribution and magnitude of chisquared errors. Disease states may deviate from monoexponential T1 relaxation more than normal brain does. The color-coded error map is a valuable tool for investigators using quantitative MR imaging to determine tissue relaxation parameters.Keywords
This publication has 14 references indexed in Scilit:
- In vivo tissue characterization of human brain by chisquares parameter maps: Multiparameter proton T2-relaxation analysisMagnetic Resonance Imaging, 1994
- Magnetic resonance relaxation time mapping in multiple sclerosis: Normal appearing white matter and the “invisible” lesion loadMagnetic Resonance Imaging, 1994
- MR evaluation of cervical cancer in hysterectomy specimens: Correlation of quantitative T2 measurement and histologyJournal of Magnetic Resonance Imaging, 1994
- Simultaneous Determination of Spin-Lattice and Spin-Spin Relaxation Times in NMR: A Robust and Facile Method for Measuring T2. Optimization and Data Analysis of the Offset-Saturation ExperimentJournal of Magnetic Resonance, Series A, 1994
- Accuracy and precision in the measurement of relaxation times from nuclear magnetic resonance imagesThe British Journal of Radiology, 1987
- Book reviewsTwo Dimensional Real Time Ultrasonic Imaging of the Heart. Ed. by GiulianiE. R., pp. 423, 1985 (Martinus Nijhoff, Boston), £82.75. ISBN 0–89838–671–3The British Journal of Radiology, 1987
- Methodology for the measurement and analysis of relaxation times in proton imagingMagnetic Resonance Imaging, 1987
- Error analysis for optimized inversion recovery spin-lattice relaxation measurementsJournal of Magnetic Resonance (1969), 1977
- The experimental approach to accurate carbon-13 spin-lattice relaxation measurementsJournal of Magnetic Resonance (1969), 1975
- Errors in measurements of transverse relaxation ratesJournal of Magnetic Resonance (1969), 1973