Pulsation failure as a consequence of milking with short teatcup liners
- 1 February 1983
- journal article
- research article
- Published by Cambridge University Press (CUP) in Journal of Dairy Research
- Vol. 50 (3) , 249-258
- https://doi.org/10.1017/s0022029900023086
Abstract
Summary: Half-udder comparisons were made using 72 and 59 cows in 2 experiments of 8 months duration to assess the incidence of pulsation failure, and its effects on teat condition and mastitis, as a consequence of milking with shortened teatcup liners. Diagonally opposite quarters of all cows were milked with control liners of 148 mm effective length or with the same liners shortened to an effective length of 110–130 mm by inserting a rigid sleeve in the lower barrel of the liner. Milking with shortened teatcup liners resulted in a high incidence of pulsation failure (defined for this experiment as failure of the liner to collapse fully beneath the teat in each pulsation cycle throughout milking). More than 50% of hind teats and 90% of front teats in the research herd penetrated deeply enough into the teatcup to prevent cyclic collapse of liners shortened to 130 mm. Such failure occurred with all teats in liners shortened to 125 mm for front teats or 110 mm for hind teats. The combined results for the 2 experiments showed that almost twice as many new mastitis infections occurred in quarters milked with the shortened liners (47 υ. 25, P < 0·01). This effect was confined to front quarters for which there was a 3-fold difference in the number of new infections (32 for the short liners υ. 11 for the controls, P < 0·001). In both lactations, significantly more teats had petechial haemorrhages when milked with the shortened liners and the electrical conductivity of milk from uninfected front quarters was higher. These results might reflect an interaction between pulsation failure and differences in the degree of overmilking that usually occur between front and hind quarters.This publication has 8 references indexed in Scilit:
- Effect of Duration of Teat Cup Liner Closure Per Pulsation Cycle on Bovine MastitisJournal of Dairy Science, 1981
- Biological responses of the bovine teat to milking: information from measurements of milk flow-rate within single pulsation cyclesJournal of Dairy Research, 1981
- Effect of deflector shields fitted in the milking machine teatcup liner on bovine udder diseaseJournal of Dairy Research, 1980
- Movement of Infection Between Milk Tubes, Teat Cups, and Teats with a Jacketed Airflow Cushion in a Single Chamber Teat CupJournal of Dairy Science, 1976
- Efficacy of the Measurement of the Electrical Conductivity of Milk for the Detection of Subclinical Mastitis in Cows: Detection of Infected Cows at a Single VisitBritish Veterinary Journal, 1975
- A comparison of the milking characteristics of transparent and conventional teatcup linersJournal of Dairy Research, 1970
- An outbreak of teat sores in a commercial dairy herd possibly associated with milking machine faultsVeterinary Record, 1970
- A SURVEY ON THE INCIDENCE OF BOVINE MASTITIS IN DAIRY HERDS IN TWO DISTRICTS IN VICTORIAAustralian Veterinary Journal, 1967