Scintigraphic Evaluation of Gastric Emptying: Are Radiolabeled Solids Necessary?
- 1 January 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 14 (1) , 40-46
- https://doi.org/10.1097/00003072-198901000-00011
Abstract
A standard, dual-isotope meal (Tc-99m-egg sandwich and In-111 DTPA in water) was administered to 14 normal volunteers and 37 patients, who had not undergone gastric surgery, to determine if the emptying characteristics of the liquid phase alone could accurately predict delayed solid emptying. Delayed gastric emptying was defined clinically as a solid half-emptying time more than two standard deviations greater than the mean for normal volunteers. Linear regression analysis was performed on the natural logarithm of liquid fractional retention at each time interval to yield a slope and y-intercept for each subject. There was no significant difference (0.6 < P < 0.8) between volunteers and patients with normal solid emptying for the liquid slope. In patients who exhibited delayed gastric emptying for solids, the liquid slopes were significantly different from the normal values (P < .001). There was a high correlation of liquid slope to solid half-emptying time in all patients and volunteers (r = - 0.80, P < .001). Comparison of the liquid slope measurement to solid half-emptying time criteria revealed a sensitivity of 96%, a specificity of 100%, and a predictive value of 100% for the slope test. These results suggest that delayed gastric emptying can be accurately detected with a liquid-solid meal using only a single-liquid label.This publication has 13 references indexed in Scilit:
- Intrinsic emptying pattern of the human stomachAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 1984
- Gastric emptying in normal subjects--a reproducible technique using a single scintillation camera and computer system.Gut, 1983
- Antral control of canine gastric emptying of solidsAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 1983
- Comparison of methods for analyzing gastric isotope emptyingAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 1982
- Gastric Emptying of a Physiologic Mixed Solid-Liquid MealClinical Nuclear Medicine, 1982
- Gastric emptying of varying meal weight and composition in manDigestive Diseases and Sciences, 1981
- Dyspepsia, antral motor dysfunction, and gastric stasis of solidsGastroenterology, 1980
- TECHNIQUES AND ERRORS IN SCINTIGRAPHIC MEASUREMENTS OF GASTRIC-EMPTYING1978
- 99mTc-Tagged chicken liver as a marker of solid food in the human stomachDigestive Diseases and Sciences, 1976
- GASTRIC-EMPTYING RATE MEASUREMENT IN MAN - DOUBLE ISOTOPE SCANNING TECHNIQUE FOR SIMULTANEOUS STUDY OF LIQUID AND SOLID COMPONENTS OF A MEAL1976