The Effect of a Chemical Protective Ensemble on Intravenous Line Insertion by Emergency Medical Technicians
Open Access
- 1 October 1999
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 164 (10) , 737-739
- https://doi.org/10.1093/milmed/164.10.737
Abstract
Protective gear is mandatory for medical personnel treating casualties in a contaminated environment. In the present study, we assessed the ability of emergency medical technicians to insert an intravenous line in this situation. Sixty emergency medical technicians were randomized to a control group, wearing fatigues, and a study group, wearing full protective gear. The ability to insert an intravenous line in healthy volunteers was assessed 1, 2, 4, and 8 hours after randomization. We found no effect of protective gear (p = 0.543) or time in protective gear (p = 0.8869) on success rate or on time needed for successful task completion (p = 0.4005 and p = 0.9021, respectively). The overall success rate was 58.6%, 65% in the unprotected state and 56% in the protected state, and the time was 303 ±115 and 351 ±113 seconds, respectively. These findings suggest that introduction of an intravenous line is possible but time consuming even after a prolonged stay in full protective gear. Alternative methods for antidotal treatment, such as the use of automatic autoinjectors for intramuscular administration, might be suggested.Keywords
This publication has 0 references indexed in Scilit: