On-Line Acquisition And Analysis For Holographic Nondestructive Evaluation

Abstract
One major reason for the limited acceptance of holographic nondestructive evaluation (HNDE) by industry is the complexity of interpreting the holographic interferograms. To alleviate this problem, we developed a system comprising a self-scanned photodiode array, microprocessor controlled acquisition subsystem, and a link to a time-sharing computer. The system is described and results demonstrating auto-mated flaw detection are presented.

This publication has 0 references indexed in Scilit: