Electrochemical Glucose and Lactate Sensors Based on “Wired” Thermostable Soybean Peroxidase Operating Continuously and Stably at 37 °C
- 1 March 1997
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (6) , 1054-1060
- https://doi.org/10.1021/ac961083y
Abstract
Following a recent report from our laboratory on a thermostable amperometric H2O2 sensor based on “wiring” soybean peroxidase, glucose and lactate sensors maintaining stable output under continuous operation at 37 °C for 12 and 8 days, respectively, were built. The vitreous carbon base of the sensor was coated with four polymer layers. The first was made by cross-linking thermostable soybean peroxidase and the redox polymer formed through complexing part of the rings of poly(vinylpyridine) with [Os(bpy)2Cl]+/2+ (bpy = bipyridine) and quaternizing part of the rings with bromoethylamine. The second was an insulating and H2O2 transport controlling cellulose acetate layer. The third was an immobilized glucose oxidase or lactate oxidase layer. The fourth was a substrate transport controlling cellulose acetate layer In the case of the glucose sensor, the current output was independent of potential between −0.2 and +0.3 V (vs SCE), and the response time (t10/90)was 2 partial pressure above 15 Torr. The sensor was relatively insensitive to motion and to interferants. Changing the rotation speed of the electrode from 50 to 2500 rpm increased the current by <10%. At a glucose concentration of 4 mM, the addition of 0.1 mM ascorbate decreased the current by <1%. The operational stability was glucose oxidase loading dependent. Though the current decreased by 85% after 100 h of operation at 37 °C when the 3-mm-diameter electrode was loaded with only 1.3 μg of glucose oxidase, it decreased by <1% after such operation when loaded with 52 μg of the enzyme. Similar results were obtained for the lactate sensor, with the exception of a more noticeable oxygen concentration dependence of the lactate response at low oxygen concentrations.Keywords
This publication has 30 references indexed in Scilit:
- Alcohol biosensors based on coupled oxidase-peroxidase systemsAnalytica Chimica Acta, 1996
- Hydrogel matrix for three enzyme entrapment in creatine/creatinine amperometric biosensingAnalytica Chimica Acta, 1996
- Bienzyme Electrode Compatible Behavior for Water-Soluble and-Insoluble SubstratesAnalytical Letters, 1996
- A bienzyme modified carbon paste electrode for the amperometric detection of l-lactate at low potentialsAnalytica Chimica Acta, 1996
- Synthesis of Protein-Doped Sol-Gel SiO2 Thin Films: Evidence for Rotational Mobility of Encapsulated Cytochrome cChemistry of Materials, 1995
- Ultrathin Porous Carbon Films as Amperometric Transducers for Biocatalytic SensorsAnalytical Chemistry, 1994
- Analysis of metabolites in sweat as a measure of physical conditionAnalytica Chimica Acta, 1994
- Amperometric biosensor for in vivo glucose sensing based on glucose oxidase immobilized in a redox hydrogelBiosensors and Bioelectronics, 1994
- Amperometric tetrathiafulvalene-mediated lactate electrode using lactate oxidase absorbed on carbon foilAnalytica Chimica Acta, 1990
- Enzyme electrodes with improved mechanical and analytical characteristics obtained by binding enzymes to nylon netsAnalytica Chimica Acta, 1983