Attenuation correction of four dimensional (4D) PET using phase-correlated 4D-computed tomography
- 19 June 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (13) , N259-N268
- https://doi.org/10.1088/0031-9155/53/13/n03
Abstract
The image quality in a conventional positron emission tomography (PET)/computed tomography (CT) scanner is degraded by respiratory motion because of erroneous attenuation correction when three-dimensional image acquisition is used. To overcome this problem, time-resolved data acquisition (4D) is required. For this, a Siemens Biograph 16 PET/CT scanner has been modified and its normal capability has been extended to a true 4D-PET/4D-CT imaging device including phase-correlated attenuation correction. To verify the correct functionality of this device, experiments on a respiratory motion phantom that allowed movement in two dimensions have been performed. The measurements showed good spatial correlation as well as good time synchronization between the PET and CT data. Furthermore, the motion pattern of the phantom and the shape of the activity distribution have been examined, and the volume of the reconstructed PET images has been analyzed. The results demonstrate the feasibility of such a procedure, and we therefore recommend that 4D-PET data should be reconstructed using 4D-CT data, which can be acquired on the same machine.Keywords
This publication has 15 references indexed in Scilit:
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006
- Technical and dosimetric aspects of respiratory gating using a pressure‐sensor motion monitoring systemMedical Physics, 2005
- Externally triggered gating of nuclear medicine acquisitions: a useful method for partitioning dataPhysics in Medicine & Biology, 2005
- Positron emission tomography/computed tomography–imaging protocols, artifacts, and pitfallsMolecular Imaging & Biology, 2004
- 4-dimensional computed tomography imaging and treatment planningSeminars in Radiation Oncology, 2004
- Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- PET-CT image co-registration in the thorax: influence of respirationEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Organ motion and its managementInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Real-time system for respiratory-cardiac gating in positron tomographyIEEE Transactions on Nuclear Science, 1998
- Uncertainties in CT-based radiation therapy treatment planning associated with patient breathingInternational Journal of Radiation Oncology*Biology*Physics, 1996