Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids
- 1 January 1998
- journal article
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 93 (1) , 92-98
- https://doi.org/10.1016/s0002-9270(97)00030-0
Abstract
The accuracy of the 13C-octanoic acid breath test is enhanced by breath sampling over 6 h rather than 4 h, but this increases the cost of the test. Our aim was to validate a less costly but accurate sequence of breath sampling for measuring gastric emptying of solids. We performed the 13C-octanoic acid breath test and tested its reproducibility relative to simultaneous scintigraphy in 30 healthy volunteers. There was a significant but weak correlation between t1/2 measured by the two tests (rs= 0.54, p < 0.005), but not between the duration of the lag phase. The differences in the t1/2 measurements between the tests were different between subjects but were highly reproducible within subjects. Within- and between-subject variations of measurements of gastric emptying with the 13C-octanoic acid breath test were not significantly different from the variations observed with scintigraphy. A subset of 11 breath samples collected over 6 h (24 samples) predicted (r2 > 0.95) the variables characterizing the cumulative appearance of 13CO2 in breath; these samples were at 35, 50, 95, 110, 140, 155, 215, 245, 260, 290, and 335 min. The accuracy of this subset of sampling times was confirmed in a separate set of breath test samples over 6 h from the same 30 subjects. The 13C-octanoic acid breath test for gastric emptying of solids is as reproducible as scintigraphy. A subset of 11 sampling times provides sufficient information to characterize the whole breath-test curve, but the sampling period should be extended to 6 h after dosing.Keywords
This publication has 0 references indexed in Scilit: