Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction
- 1 October 2003
- journal article
- clinical trial
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 30 (10) , 1330-1337
- https://doi.org/10.1007/s00259-003-1231-0
Abstract
Electrocardiographic (ECG) gated single-photon emission tomography (SPET) allows for simultaneous assessment of myocardial perfusion and left ventricular (LV) function. Presently 8-frame per cardiac cycle ECG gating of SPET images is standard. The aim of this study was to compare the effect of 8-frame and 16-frame gated SPET on measurements of LV volumes and to evaluate the effects of the presence of myocardial perfusion defects and of radiotracer dose administered on the calculation of LV volumes. A total of 86 patients underwent technetium-99m SPET myocardial perfusion imaging using 16-frame per cardiac cycle acquisition. Eight-frame gated SPET images were generated by summation of contiguous frames. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated from the 16-frame and 8-frame data sets. The patients were divided into groups according to the administered dose of the radiotracer and the size of the perfusion defect. Results. Sixteen frame per cardiac cycle acquisition resulted in significantly larger EDV (122±72 ml vs 115±68 ml, P P P<0.0001) as compared to 8-frame SPET imaging. This effect was seen regardless of whether a high or a low dose was administered and whether or not significant perfusion defects were present. This study shows that EDV, ESV and LVEF determined by 16-frame gated SPET are significantly different from those determined by 8-frame gated SPET. The radiotracer dose and perfusion defects do not affect estimation of LV parameters by 16-frame gated SPET.Keywords
This publication has 23 references indexed in Scilit:
- Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: experimental validation using MRI.2000
- 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography.1999
- Quantification of SPECT myocardial perfusion images: Methodology and validation of the Yale-CQ methodJournal of Nuclear Cardiology, 1999
- Relationship of gated SPECT ventricular function parameters to angiographic measurementsJournal of Nuclear Cardiology, 1998
- Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin.1997
- Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact.1995
- End-systolic volume and long-term survival after coronary artery bypass graft surgery in patients with impaired left ventricular function.Circulation, 1994
- Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data.1994
- Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities.1993
- Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction.Circulation, 1987