The influence of 241-Am and DTPA on morphometric parameters of the rat femur
- 1 March 1976
- journal article
- research article
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 13 (1) , 27-41
- https://doi.org/10.1007/bf01323621
Abstract
Microradiographically detectable alterations of the bone structure in the femur of young rats induced by monomeric 241-Am(III) (i.v., 30µCi/kg) were studied. The morphometric and dosimetric measurements were carried out by means of an electronic image analyzer. 8 weeks after injection of 241-Am a characteristic alteration of the frequency distribution of the chord lengths over the trabeculae in the epiphysis and over the metaphyseal marrow spaces was found. The structure of the spongiosa is irregular with both large, coarse and small fragmented trabeculae. The complexity of the bone architecture and the area of the endosteal surfaces is reduced. The surface/volume ratio in control animals varies between 36 mm−1 in the epiphysis and 64 mm−1 in the region of the epiphyseal cartilage plate. From the specific surface burden (pCi/mm2) the average dose rates were determined. There is no significant difference between the calcified tissue fraction in controls and animals with 241-Am, with the exception of the metaphyseal band where the locally high dose rates cause a devitalization of the tissue with inhibition of bone resorption as well as an abnormal trabeculation in the metaphysis. Treatment by Ca-DTPA reduces the 241-Am deposition nonuniformly and the pathological manifestations are markedly less pronounced. The mean trabecular width is about 100µm in the epiphysis and has a minimum of 40µm in the central part of the epiphyseal plate. The mean chord length over the marrow spaces varies between 90 and 210µm.Keywords
This publication has 10 references indexed in Scilit:
- Topographic Analysis of the Microdistribution of 241 Am in the Rat Femur as Influenced by DTPA TreatmentRadiation Research, 1976
- Automatic determination of high α-track densities in polymer detectorsThe International Journal of Applied Radiation and Isotopes, 1975
- α-microdosimetry in bone sections by means of dielectric track detectors and electronic image analysisThe International Journal of Applied Radiation and Isotopes, 1975
- Quantitative Characterization of Bone: A Computer Analysis of MicroradiographsPublished by Wolters Kluwer Health ,1971
- Quantitative structural analysis of human cancellous boneCells Tissues Organs, 1970
- Surface to Volume Ratios of Bone determined by Computer Analysis of MicroradiographsNature, 1968
- Comparison of some Quantitative Studies of Trabecular BonePublished by Springer Nature ,1967
- Quantitative Histological Study of Human Lumbar VertebraeJournal of Gerontology, 1966
- A Computer Programme for Automatic Scanning of Autoradiographs and Microradiographs of Bone SectionsNature, 1966