AAPM/RSNA Physics Tutorial for Residents: Topics in CT
Top Cited Papers
- 1 November 2002
- journal article
- review article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 22 (6) , 1541-1553
- https://doi.org/10.1148/rg.226025128
Abstract
This article describes basic radiation dose concepts as well as those specifically developed to describe the radiation dose from computed tomography (CT). Basic concepts of radiation dose are reviewed, including exposure, absorbed dose, and effective dose. Radiation dose from CT demonstrates variations within the scan plane and along the z axis because of its unique geometry and usage. Several CT-specific dose descriptors have been developed: the Multiple Scan Average Dose descriptor, the Computed Tomography Dose Index (CTDI) and its variations (CTDI(100), CTDI(w), CTDI(vol)), and the dose-length product. Factors that affect radiation dose from CT include the beam energy, tube current-time product, pitch, collimation, patient size, and dose reduction options. Methods of reducing the radiation dose to a patient from CT include reducing the milliampere-seconds value, increasing the pitch, varying the milliampere-seconds value according to patient size, and reducing the beam energy. The effective dose from CT can be estimated by using Monte Carlo methods to simulate CT of a mathematical patient model, by estimating the energy imparted to the body region being scanned, or by using conversion factors for general anatomic regions. Issues related to radiation dose from CT are being addressed by the Society for Pediatric Radiology, the American Association of Physicists in Medicine, the American College of Radiology, and the Center for Devices and Radiological Health of the Food and Drug Administration.Keywords
This publication has 28 references indexed in Scilit:
- Dose and Pitch Relationship for a Particular Multislice CT ScannerAmerican Journal of Roentgenology, 2001
- Helical CT of the BodyAmerican Journal of Roentgenology, 2001
- Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CTAmerican Journal of Roentgenology, 2001
- Minimizing Radiation Dose for Pediatric Body Applications of Single-Detector Helical CTAmerican Journal of Roentgenology, 2001
- Effective doses to patients undergoing thoracic computed tomography examinationsMedical Physics, 2000
- Performance evaluation of a multi-slice CT systemMedical Physics, 1999
- Radiation dose in Spiral CT: The relative effects of collimation and pitchMedical Physics, 1999
- CT scanner dosimetry.The British Journal of Radiology, 1998
- A method for describing the doses delivered by transmission x-ray computed tomographyMedical Physics, 1981
- Radiation Dosimetry In Computed Tomography (CT)Published by SPIE-Intl Soc Optical Eng ,1977