Normal human blood density gradient lymphocyte subset analysis: I. An interlaboratory flow cytometric comparison of 85 normal adults
- 1 September 1985
- journal article
- research article
- Published by Wiley in American Journal of Hematology
- Vol. 20 (1) , 41-52
- https://doi.org/10.1002/ajh.2830200107
Abstract
An interlaboratory flow cytometric comparison of several commercially available human lymphocyte subset reagents was undertaken in three different laboratories. Fresh Hypaque‐Ficoll purified blood mononuclear cells were stained at 4°C or 22°C. Direct or indirect surface immunofluorescence was carried out at all sites using an EPICS V flow cytometer. Fullbright, 10‐μm fluorescent polystyrene microspheres were used for optical alignment and standardization. A log integral fluorescent histogram gated on forward and right angle scatter was collected on 1–2 × 104 cells for each reagent and the proportion, of positive cell determined for each reagent. With the exception of one reagent, anti‐B1, which showed an approximately twofold variation, all three laboratories showed remarkable agreement. Thus there was no significant difference noted for the following reagents: OKT4, CCT4, Leu 3a, Leu 2a, OKT8, or CCT8. We attribute these findings to the availability of quality reagents, precision instrumentation, and a standard lymphocyte preparation.Keywords
This publication has 21 references indexed in Scilit:
- Applications of flow cytometry in clinical diagnosisTrAC Trends in Analytical Chemistry, 1984
- Three‐color immunofluorescence analysis of leu antigens on human peripheral blood using two lasers on a fluorescence‐activated cell sorterCytometry, 1984
- Immunoregulatory subsets of the T helper and T suppressor cell populations in homosexual men with chronic unexplained lymphadenopathy.Journal of Clinical Investigation, 1984
- Acquired Immunodeficiency of Blood Stored OvernightNew England Journal of Medicine, 1983
- Stability of human lymphocyte differentiation antigens when stored at room temperatureJournal of Immunological Methods, 1983
- Lymphocyte Subpopulations Altered during Blood StorageNew England Journal of Medicine, 1983
- Human T lymphocyte differentiation antigens: Effects of blood sample storage on LEU antibody bindingCytometry, 1983
- Clinical application of flow cytometry: A reviewCytometry, 1981
- Detection of Small Numbers of Monoclonal B Lymphocytes in the Blood of Patients with LymphomaNew England Journal of Medicine, 1979
- Identification, Enumeration, and Isolation of B and T Lymphocytes from Human Peripheral BloodScandinavian Journal of Immunology, 1974